YOKOGAWA FU20-FTS Instruction Manual Download Page 3

 

IM 12B06J03-05EN-P 

 

 

 

(LV) 
Visas ATEX Ex kategorijas izstrâdâjumu 
Lietoðanas instrukcijas tiek piegâdâtas 
angïu valodâs. Ja vçlaties saòemt Ex 
ierîèu dokumentâciju citâ valodâ, Jums ir 
jâsazinâs ar firmas Jokogava (Yokogawa) 
tuvâko ofisu vai pârstâvi. 
 
(LT) 
Visos gaminiø ATEX Ex kategorijos 
Eksploatavimo instrukcijos teikiami anglø 
kalbomis. Norëdami gauti priestaisø Ex 
dokumentacijà kitomis kalbomis susisiekite 
su artimiausiu bendrovës Yokogawa biuru 
arba atstovu. 
 
(M) 
Il-

manwali kollha ta’ l-istruzzjonijiet għal 

prodotti marbuta ma’ ATEX Ex huma 
disponibbli bl-

Ingliż. Jekk tkun teħtieģ 

struzzjonijiet marbuta 

ma’ Ex fil-lingwa 

lokali tiegħek, għandek tikkuntattja lill-
eqreb rappreżentan jew uffiććju ta’ 
Yokogawa. 
 
(NL) 
Alle handleidingen voor producten die te 
maken hebben met ATEX 
explosiebeveiliging (Ex) zijn verkrijgbaar in 
het Engels. Neem, indien u aanwijzingen 
op het gebied van explosiebeveiliging 
nodig hebt in uw eigen taal, contact op 
met de dichtstbijzijnde vestiging van 
Yokogawa of met een vertegenwoordiger. 
 
(P) 
Todos os manuals de instruções 
referentes aos produtos Ex da ATEX 
estão disponíveis em Inglês. Se necessitar 
de instruções na sua língua relacionadas 
com produtos Ex, deverá entrar em 
contacto com a delegação mais próxima 
ou com um representante da Yokogawa. 
 
 
 
 
 

(PL) 
Wszystkie instrukcje obsługi dla urządzeń 
w wykonaniu przeciwwybuchowym Ex, 
zgodnych z wymaganiami ATEX, 
dostępne są w języku angielskim. Jeżeli 
wymagana jest instrukcja obsługi w 
Państwa lokalnym ję zyku, prosimy o 
kontakt z najbliższym biurem Yokogawy. 
 
(RO) 
Toate manualele de instructiuni pentru 
produsele ATEX Ex sunt in limba engleza. 
In cazul in care doriti instructiunile in limba 
locala, trebuie sa contactati cel mai 
apropiat birou sau reprezentant 
Yokogawa. 
 
(S) 
Alla instruktionsböcker för ATEX Ex 
(explosionssäkra) produkter är tillgängliga 
på engelska. Om Ni behöver instruktioner 
för dessa explosionssäkra produkter på 
annat språk, skall Ni kontakta närmaste 
Yokogawakontor eller representant. 
 
(SF) 
Kaikkien ATEX Ex-tyyppisten tuotteiden 
käyttöhjeet ovat saatavilla englannin-. 
Mikäli tarvitsette Ex-tyyppisten tuotteiden 
ohjeita omalla paikallisella kielellännne, 
ottakaa yhteyttä lähimpään Yokogawa-
toimistoon tai -edustajaan. 
 
(SK) 
Všetky návody na obsluhu pre prístroje s 
ATEX Ex sú k dispozícii v jazyku 
anglickom. V prípade potreby návodu pre 
Ex-

prístroje vo Vašom národnom jazyku, 

skontaktujte prosím miestnu kanceláriu 
firmy Yokogawa. 
 
(SLO) 
Vsi predpisi in navodila za AEX Ex sorodni 
pridelk

i so pri roki v anglišèini. Èe so Ex 

sorodna navodila potrebna v vašem 
tukejnjem jeziku, kontaktirajte vaš najbliši 
Yokogawa office ili predstaunika. 

 
 

 

 

Summary of Contents for FU20-FTS

Page 1: ...IM 12B06J03 05EN P 1st edition Instruction Manual Model FU20 FTS MTS Differential pH ORP sensor...

Page 2: ...oole E Todos los manuales de instrucciones para los productos antiexplosivos de ATEX est n disponibles en ingl s Si desea solicitar las instrucciones de estos art culos antiexplosivos en su idioma loc...

Page 3: ...com a delega o mais pr xima ou com um representante da Yokogawa PL Wszystkie instrukcje obs ugi dla urz dze w wykonaniu przeciwwybuchowym Ex zgodnych z wymaganiami ATEX dost pne s w j zyku angielskim...

Page 4: ...cations 8 2 9 Regulatory standards 9 3 INSTALLATION OF 21 FU20 FTS MTS 21 3 1 Typical installation 21 3 2 Preparing the sensor for use 21 3 3 Mounting the sensor 21 3 4 Mounting FU20 FTS MTS using qui...

Page 5: ...FU20 FTS MTS comes with a multipole VP connector and requires separate cable type WU10 V D or WE10 H D that are available in several lengths Additionally the models type VP and VS can be mounted in al...

Page 6: ...cess environmental conditions that may be related to the failure of the sensor Statement as to whether warranty or non warranty service is requested Complete shipping and billing instructions for retu...

Page 7: ...a 2 of theoretical value Note The temperature sensor included in the FU20 FTS MTS is designed for process compensation and for indication It is NOT designed for process temperature control 2 4 Dynamic...

Page 8: ...L x W x H 300 x 100 x 75 mm 11 8 x 3 9 x 3 0 inch Package weight max 0 33 kg 0 73 lbs 2 7 Environmental conditions Storage temperature 10 to 50 C 14 to 122 F Ingress Protection IP67 conform IEC 60529...

Page 9: ...e maximum process pressure LVD Directive 2014 35 EU Applying standards NEN EN IEC 61010 1 ANSI ISA 61010 1 CAN CSA C22 2 No 61010 1 Note 1 Models without ID chip with fixed cable or VP type I O signal...

Page 10: ...ame certificate number is created with a new issue number ATEX DEKRA11ATEX0014 X issue 1 effective from 03 2011 DEKRA11ATEX0014 X issue 2 effective from 02 2021 IECEx IECEx DEK 11 0064X issue 0 effect...

Page 11: ...rameters Ui 18 V Ii 170 mA Pi 0 4 W Li 0 1 mH models with fixed cable or Li 0 mH VS VP type Ci 150 nF models with fixed cable or Ci 0 4 nF VS type or Ci 0 nF VP type Ambient temperature 40 C to 40 C f...

Page 12: ...12 IM 12B06J03 05EN P Control drawing D E 2020 023 A50 part 1...

Page 13: ...Option Codes FU20 ab cd efg h ab Connection type Two alphanumeric characters identifying the length of the permanent cable each character from 0 to 9 VP Connector without ID chip VS Connector with ID...

Page 14: ...14 IM 12B06J03 05EN P Control drawing D E 2020 023 A50 part 2 SA11 P2...

Page 15: ...uired isolation 5 Sensor Model code Table 4 Model Suffix Codes Option Codes FU20 ab cd efg h ab Connection type VS Connector with ID chip cd Temperature sensor Region T1 Pt1000 IS for ATEX IECEx FM US...

Page 16: ...8V Ii 170 mA Pi 0 4 W Li 0 1 mH models with fixed cable or Li 0 mH VS VP type Ci 150 nF models with fixed cable or Ci 0 4 nF VS type or Ci 0 nF VP type Ambient temperature 40 C to 40 C for temperature...

Page 17: ...17 IM 12B06J03 05EN P Control drawing D E 2020 023 A51 part 1...

Page 18: ...ID chip cd Temperature sensor Region T1 Pt1000 IS for ATEX IECEx FM US FM CAN efg Type FTS PVDF body Tapered Thread Dome shaped Sodium ions sensitive membrane Silicon Viton sealings MTS PVDF body Tape...

Page 19: ...19 IM 12B06J03 05EN P Control drawing D E 2020 023 A51 part 2 SA11 P2...

Page 20: ...d Temperature sensor Region T1 Pt1000 IS for ATEX IECEx FM US FM CAN efg Type FTS PVDF body Tapered Thread Dome shaped Sodium ions sensitive membrane Silicon Viton sealings MTS PVDF body Tapered Threa...

Page 21: ...tal plane to eliminate air bubbles in the pH glass bulb see Figure 3 Figure 3 Sensor installation 3 2 Preparing the sensor for use Remove the sensor from its shipping box and slide of the so called we...

Page 22: ...n the process connection Tighten the adapter using a wrench on the adapter flats 3 Apply Teflon tape to the appropriate threaded end of the sensor 4 Place the O ring and screw the mating part of the a...

Page 23: ...Do not undo the part in the metal tube 5 Lead the sensor cable through the tube of the fitting from the side where the knurled knob has been removed Attach the sensor and cable as usual 6 Hold the se...

Page 24: ...2B06J03 05EN P Figure 7 Installation examples for the FU20 Fitting O ring Adapter FPS FU20 O ring FU20 FD40 Cleaning solution water acid etc K1547PH K1547PF 60mm HCNF SPRAY CLEANER FU20 adapter Proces...

Page 25: ...N P 4 DIMENSIONS Dimensions in mm inches Figure 8 Dimensions FU20 FTS MTS Figure 9 Dimensions 1 FU20 FTS MTS adapter Stainless Steel Titanium and FU20 FTS MTS adapter for FF40 FS40 and FD40 fittings N...

Page 26: ...nnector layout Table 7 Figure 12 Connection diagram connector type Note Preferred connection cable is Yokogawa Model WU10 V D or Model WE10 Pin no Description VP type Description VS type A pH pH B Ref...

Page 27: ...just the pH reading in the pH analyzer to the value indicated on the bottle in this case 7 00 Go to solution 2 to do a 2 point calibration 4 Rinse sensor thoroughly with tap water 5 Immerse the sensor...

Page 28: ...ng the complete sensor with solution Some cleaning solutions will damage the model code sticker and connector which are placed on top of the sensor Only clean the measuring elements at the bottom side...

Page 29: ...t T1 T2 Pt1000 Pt100 n a for FTD and VS Model NPT FSM FTD FTS MTS Dome shape model heavy duty Flat surface model self cleaning Dome shape model chemical resistant Differential pH sensor Differential p...

Page 30: ...K1547PG Hastelloy nozzle and mounting set HCNF K1547PH Nylon tube 10 meter and tube mounting set for chemical cleaning system K1520BF Buffer solutions Buffer solution pH 4 7 9 pNa 0 500 ml each ionic...

Page 31: ...L COMPATIBILITY CHART Table 11 Note Information in this list is based on our general experience and literature data and given in good faith However Yokogawa is unable to accept responsibility for clai...

Page 32: ...32 IM 12B06J03 05EN P IM 12B06J03 05EN P Printed in The Netherlands 01 2101 Subject to change without notice Copyright...

Reviews: