YOKOGAWA Dpharp EJA118N User Manual Download Page 75

IM 1C22H1-01E

REVISION RECORD

Title: Model EJA118W, EJA118N, and EJA118Y Diaphragm Sealed Differential

Pressure Transmitter

Manual No.: IM 1C22H1-01E

Edition

Date

Page

Revised Item

8th

Mar. 1998

1-1
4-5

5-1

10-1
10-3
10-7
2-9+

CMPL

1
4.4

5.1
10.1.1
10.1.2
10.1.3

CMPL 1C22A1-02E 3rd       4th
Page 2

• Add FOUNDATION Fieldbus protcol version to ‘NOTE’ notice.
• Correct Teflon film Part Number.
F9347YD (Incorrect)       F9347YA (Correct)
• Add Item 6 to the Wiring Precautions.
• Add FOUNDATOIN Fieldbus protocol.
• Add Output signal code F.
• Add Optional code A1.
• Change the figure of terminal configuration.

• Add Item 7-2.

REVISION RECORD.EPS

9th

Sep. 1998

2-14

2-15
7-20
10-3

10-4

10-5

CMPL

2.10

2.10
7.3.2(11)
10.1.2

CMPL 1C22A1-02E 4th       5th
Page 2

CMPL 1C22H1-01E 1st       2nd
Page 4

• Delete EMC Conformity Standards Tables and move the section 
to Page 2-14.
• Remove Page 2-15.
• Correction made in BURN OUT figure.
• Add Process flange size / material code F and C.
• Add Electrical connection code 7, 8, and 9.
• Add Process flange size / material code F and J.
• Add Electrical connection code 7, 8, and 9.
• Add Process flange size / material code R.
• Add Electrical connection code 7, 8, and 9.

• Add Part No. to Item 3 (For PG13.5 and M20).
• Add Part No. to Item 10 (For 1/2NPT, PG13.5, and M20).

• Add SUS316 Stainless Steel Part No. to Flange material in 
Table 1.
• Part No. correction made in Table1.

(Incorrect)

(Correct)

F9315KA

F9351KA

F9315KB

F9351KB

F9315GA

F9351GA

F9315GB

F9351GB

10th

Feb. 2000

2-9

4-1

5-1
5-3

7-4

Changed to Electronic File Format.
Revised a book in a new format.

(The location of contents and the associated page numbers may 
not coincide with the one in old editions.)

Major Revised Items:

2.9
2.10
4.2

5.2
5.4.2

7.3.1

1. Explosion class and option code of JIS flameproof approval.

Explosion class: Ex ds IIC T4(old) to Ex do IIC T4X(new).
Option code: /JF1(old) to /JF3(new)

2. Option code for flameproof packing adapter for JIS flameproof 

approval.
Option code: /G1 and /G2(old) to /G11 and /G12(new)

3. Add “Pa” and “hPa” as the unit for calibration range.
4. Part number change for CPU Board Assembly.

• Add Figure 2.3 Example of using DCS.
• Add AS/NZS 2064 1/2 to EMI, EMC Conformity Standards.
• Correct the place of the high and low identification labels for 
remote diaphragm seals.
• Add selection in the case of JIS flameproof type.
• Change option code for flame packing adapter.
Option code: G1 and G2 

    

 G11 and G12

Change Applicable cable O.D. and Identifying mark.
Part number: G9601AH      G9601AM
Change the figure of flame proof packing adapter in Figure 5.4.2c.
• Add Pa and hPa to C20 and D31.

Summary of Contents for Dpharp EJA118N

Page 1: ...Instruction Manual Y okogawa Electric Corporation Model EJA118W EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters Style S2 IM 1C22H1 01E IM 1C22H1 01E 10th Edition...

Page 2: ...Blank Page...

Page 3: ...Certification 2 7 2 9 5 JIS Certification 2 9 2 10 EMC Conformity Standards 2 9 3 COMPONENT NAMES 3 1 4 INSTALLATION 4 1 4 1 Precautions 4 1 4 2 Mounting the Diaphragm Seals 4 1 4 3 Transmitter Mount...

Page 4: ...7 4 7 3 2 Parameter Usage and Selection 7 6 7 3 3 Setting Parameters 7 7 1 Tag No Setup 7 7 2 Calibration Range Setup 7 7 3 Damping Time Constant Setup 7 8 4 Output Mode and Integral Indicator Display...

Page 5: ...w Charts 8 5 9 GENERAL SPECIFICATIONS 9 1 9 1 Standard Specifications 9 1 9 2 Model and Suffix Codes 9 3 9 3 Optional Specifications 9 6 9 4 Dimensions 9 8 INSTALLATION AND OPERATING PRECAUTIONS FOR J...

Page 6: ...Blank Page...

Page 7: ...evisions will not cause difficulty to the user from a functional or performance standpoint NOTE For FOUNDATION Fieldbus and HART protocol versions please refer to IM 1C22T2 01E and IM 1C22T1 01E respe...

Page 8: ...conditions Use of the product in question in a location not conforming to the standards specified by Yokogawa or due to improper maintenance of the installation location Failure or damage due to modif...

Page 9: ...SQRT is inscribed in field 2 if square root output mode was ordered SQRT is inscribed in field 3 Figure 2 2 Name Plate Example of JIS Flameproof Type 2 2 Unpacking When moving the transmitter to the i...

Page 10: ...n WARNING Instrument installed in the process is under pressure Never loosen or tighten the flange bolts to avoid the dangerous spouting of process fluid Since the accumulated process fluid may be tox...

Page 11: ...it is discharging Dielectric Strength Test 1 Short circuit the and SUPPLY terminals in the terminal box 2 Turn OFF the dielectric strength tester Then connect the tester between the shorted SUPPLY te...

Page 12: ...rized representative of Yokogawa Electric Corporation is prohibited and will void Factory Mutual Intrinsically safe and Nonincendive Approval F0203 EPS Class I II III Division 1 Groups A B C D E F G E...

Page 13: ...T4 Ambient temperature 40 to 60 C Process Temperature 120 C max Note 2 Entity Parameters Intrinsically safe ratings are as follows Maximum Input Voltage Vmax 30 V Maximum Input Current Imax 165 mA Max...

Page 14: ...U1 can be selected the type of protection CSA Intrinsically Safe or CSA Explosionproof for use in hazardous locations Note 1 For the installation of this transmitter once a particular type of protecti...

Page 15: ...nance and Repair The instrument modification or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void Standards Association of Australi...

Page 16: ...plosive atmospheres Type of Protection and Marking Code Ex nA IIC T4 Temperature Class T4 Process Temperature 120 C max Ambient Temperature 40 to 60 C Note 2 Electrical Data Supply and output circuit...

Page 17: ...ation and Operating Precautions for JIS Intrinsi cally Safe Equipment and Flameproof Equipment at the end of this manual CAUTION For JIS flameproof type without integral indicator When the fill fluid...

Page 18: ...onnection Note 1 CPU assembly Setting pin CN4 Note 1 Options depend on your order specifications For details see Subsection 9 2 Model and Suffix Codes Note 2 Insert the pin CN4 as shown in the above f...

Page 19: ...ectly Refer to Subsection 9 4 Dimensions IMPORTANT When measuring the liquid level of the tank the minimum liquid level zero point must be set to a level at least 50 mm above the center of the high pr...

Page 20: ...st 600 mm below the high pressure HP process connection to ensure a positive head pressure of fill fluid Pay special attention to vacuum applica tions If it can not be installed at least 600 mm below...

Page 21: ...the air by starting at the center of the diaphragm and work your way out 5 Place the gasket with the teflon film and affix to the process flange Teflon film Diaphragm Fluorinated oil PART No F9145YN G...

Page 22: ...or correct wiring 5 2 Selecting the Wiring Materi als a Use stranded leadwires or cables which are the same as or better than 600 V grade PVC insulated wire JIS C3307 or equivalent b Use shielded wire...

Page 23: ...S Intrinsically Safe Equipment and Installation and Operating Precautions for JIS Flameproof Equipment at the end of this manual prior to the work 5 4 1 Loop Configuration Since the DPharp uses a two...

Page 24: ...ter nearest to this value see Table 5 4 2 Table 5 4 2 Flameproof Packings and Applicable Cable Outer Diameters T0501 EPS G9601AM 8 to 10 10 1 to 12 16 8 10 16 10 12 G 1 2 G11 G12 Optional Code Wiring...

Page 25: ...ing is required for JIS flameproof type and intrinsically safe type Note If equipped with built in Lightning Protector grounding should satisfy Special JIS class 3 requirements grounding resistance 10...

Page 26: ...gm seal low pressure side Figure 6 1 1 Liquid Level Measurement in a Closed Tank j Confirming that Transmitter is Operating Properly Confirmation using the BT200 If the wiring system is faulty communi...

Page 27: ...efore adjusting a screw check that the parameter J20 EXT ZERO ADJ displays ENABLE See Subsection 7 3 3 12 for the setting procedure Use a slotted screwdriver to turn the zero adjustment screw Turn the...

Page 28: ...er output signal Confirm the hunting using a receiv ing instrument or the integral indicator and set the optimum damping time constant See Subsection 7 3 3 3 Damping Time Constant Setup 2 After confir...

Page 29: ...signal in Note 2 9 Adjust the output signal to 100 5 V DC by rotating the external zero adjustment screw Doing so completes the HRV setting 10 Press the range setting push button The transmitter then...

Page 30: ...ntrol room Terminal board F0701 EPS Figure 7 1 1 Connecting the BT200 7 1 2 Conditions of Communication Line DPharp BT200 Cable resistance Rc Cable resistance Rc Load resistance R cc Power supply d Lo...

Page 31: ...on key F1 CODE to enter symbols The following symbols will appear in sequence one at a time at the cursor each time you press F1 CODE To enter characters next to these symbols press to move the cursor...

Page 32: ...ge of messages Japanese or English 4 LCD contrast setting 5 Adjusting printout tone BT200 P00 only FUNC 1 MENU 2 UPLOAD TO BT200 3 DOWNLOAD TO INST 4 PRINT ALL DATA HOME SET ADJ ESC MENU A DISPLAY B S...

Page 33: ...TEMP CAP OVER TEMP AMP OVER OUTPUT OVER DISPLAY ILLEGAL LRV ILLEGAL HRV ILLEGAL SPAN and ZERO ADJ OVER Self diagnostic messages A60 SELF CHECK In case of Model EJA120 static pressure cannot be measur...

Page 34: ...sages J60 SELF CHECK Display the error History of the errors RECORD Last error P10 P11 ERROR REC 1 Display the error One time before ERROR REC 2 P12 Display the error Two time before ERROR REC 3 Menu...

Page 35: ...y decimal point within the range of 19999 to 19999 T0707 EPS Unit setup for displayed temperature c P 7 11 Sets a unit for temperatures displayed on the BT200 Unit setup for displayed static pressure...

Page 36: ...AWA CODE CAPS CLR ESC When you have made an entry mistake return the cursor using the key then reenter Set the new TAG NO FIC 1a FOKOGAWA FIKOGAWA FICOGAWA FIC GAWA FIC 1AWA FIC 1aWA FIC 1a Set TAG NO...

Page 37: ...up to 5 digits excluding any decimal point for low or high range limits within the range of 32000 to 32000 Example 2 With present settings of 0 to 30 kPa set the Higher range value to10 kPa FEED NO OK...

Page 38: ...OUT SQR DSP SQR Use the or key to select OUT LIN DSP SQR Press the key twice to enter the setting Press the OK key F0716 EPS 5 Output Signal Low Cut Mode Setup D10 LOW CUT D11 LOW CUT MODE Low cut mo...

Page 39: ...mits within the range of 19999 to 19999 See a through c for each setting procedure indication and input pressure indication Transmitter is set for display when shipped D20 DISP SELECT NORMAL INP PRES...

Page 40: ...shipped these are set as specified in the order Follow the procedure below to change these settings Note that these parameters need not be set for display Example Set lower range value LRV to 50 and...

Page 41: ...nter the setting F0726 EPS 11 Output Status Display Setup when a CPU Failure D52 BURN OUT This parameter displays the status of 4 to 20 mA DC output if a CPU failure occurs In case of a failure commun...

Page 42: ...nge while Applying Actual Inputs H10 AUTO LRV H11 AUTO HRV This feature allows the lower and higher range values to be set up automatically with the actual input applied If the lower and higher range...

Page 43: ...zero adjustment screw on the transmitter This permits zero adjustment without using the BT200 Accurately adjust the output current to 4 mA DC or other target output value using an ammeter that accura...

Page 44: ...the range setting Note that the amount of adjustment to the zero point changes according to the speed at which the screw is turned To make fine adjustments turn the screw slowly to make coarse adjust...

Page 45: ...F0741 EPS For the associated parameters see Subsection 7 3 1 Parameter Summary 7 5 Self Diagnostics 7 5 1 Checking for Problems 1 Identifying Problems with BT200 The following four areas can be check...

Page 46: ...r two hours from when an error occurs the error message of that error will be recorded Therefore if you switch off the transmitter within two hours from when the error occurs there is no history of th...

Page 47: ...oblem Input is outside measurement range limit of capsule Displays present output Displays present output Displays present output Outputs high or low range limit value Displays high or low range limit...

Page 48: ...2 1 shows the instruments required for calibra tion Select instruments that will enable the transmitter to be calibrated or adjusted to the required accuracy The calibration instruments should be hand...

Page 49: ...o 133 kPa 1000 mmHg Prepare the vacuum pump for negative pressure ranges Dead weight gauge tester 25 kPa 2500mmH2O Accuracy 0 03 of setting Select a pressure generator having a pressure range close to...

Page 50: ...ng bolt without fail Tighten the shrouding bolt to a torque of 0 7 N m Shrouding bolt Shrouding bolt F0802 EPS Figure 8 4 1 Shrouding Bolts 8 4 1 Replacing the Integral Indicator This subsection descr...

Page 51: ...e with black connec tor at the end that connects the CPU assembly and the capsule NOTE Be careful not to apply excessive force to the CPU assembly when removing it j Mounting the CPU Assembly 1 Connec...

Page 52: ...environmental conditions Inspect receiver Check transmitter Check correct operating conditions Measurement system problem F0804 EPS YES NO NO YES Environmental conditions Operating conditions Transmi...

Page 53: ...re power supply voltage and load resistance correct Is external noise contained in the outout Refer to error message summary in Subsection 7 5 2 to take actions Bind capillaries together as far as pos...

Page 54: ...Constant approx sec 1 5 1 0 M H T0902 EPS Capsule Silicone Oil When the capillary length 3 m and the fill fluid code A Ambient Temperature Limits Safety approval codes may affect limits 40 to 60 C 40...

Page 55: ...22 to 3568F 15 to 608C 5 to 1408F 10 to 3008C 50 to 5728F 10 to 608C 50 to 1408F 20 to 1208C 4 to 2488F 10 to 608C 14 to 1408F 50 to 1008C 58 to 2128F 40 to 608C 40 to 1408F Fill Fluid Code A Fill Flu...

Page 56: ...JIS SUS304 2 inch 50 mm JIS SUS316 JIS SCM435 JIS SUS630 Process temp Ambient temp For general use silicone oil 10 to 2508C 10 to 608C For general use silicone oil 30 to 1808C 15 to 608C For high temp...

Page 57: ...SUS304 3 inch 80 mm JIS SUS316 JIS SCM435 JIS SUS630 Process Ambient temperature temperature For general use silicone oil 10 to 250 8C 10 to 60 8C For general use silicone oil 30 to 180 8C 15 to 60 8...

Page 58: ...High pressure side 4 inch 100 mm JIS SUS316 Low pressure side 3 inch 80 mm JIS SUS316 JIS SCM435 JIS SUS630 Process Ambient temp temp For general use silicone oil 10 to 250 8C 10 to 60 8C For general...

Page 59: ...Li 730 mH Electrical connection 1 2 NPT female FS1 CENELEC KEMA Flameproof Approval EExd IIC T4 T5 T6 Amb Temp 40 to 80 8C 40 to 176 8F Max process Temp T4 120 8C 248 8F T5 100 8C 212 8F T6 85 8C 185...

Page 60: ...Amplifier cover only D1 D3 P calibration psi unit bar calibration bar unit See Table for Span and Range Limits Calibration units Note 1 D4 M calibration kgf cm2 unit Epoxy resin baked coating Color ch...

Page 61: ...100 3 94 100 3 94 100 3 94 100 3 94 100 3 94 100 3 94 100 3 94 100 3 94 100 3 94 100 3 94 d 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 61 2 40 f 0 0 0 1 6...

Page 62: ...8 8 8 8 8 8 8 8 h 19 0 75 23 0 91 19 1 0 75 22 4 0 88 19 0 75 22 0 87 18 0 71 22 0 87 g 155 6 10 155 6 10 155 6 10 155 6 10 155 6 10 155 6 10 155 6 10 155 6 10 A 96 3 78 96 3 78 96 3 78 96 3 78 96 3...

Page 63: ...ass 300 JPI Class 150 JPI Class 300 DIN PN 10 16 DIN PN 25 40 D 185 7 28 200 7 87 190 5 7 50 209 6 8 25 190 7 48 210 8 27 200 7 78 200 7 78 t 18 0 71 22 0 87 23 9 0 94 28 5 1 12 24 0 94 28 5 1 12 20 0...

Page 64: ...used in compliance with the specifications marked on its certification label equipment nameplate and precautionary information furnished Note Intrinsically safe apparatus satisfy their performance un...

Page 65: ...ination require ments by referring to its safety rating and combination parameters shall be selected 2 For pressure transmitters pH transmitters temperature detectors and the like safety barriers that...

Page 66: ...nstallation such as wiring method earthing or the like if any and f protect the outer sheath of cables from damage with appropriate measures 7 Maintenance and Inspection of Intrinsically Safe Apparatu...

Page 67: ...cation label equipment nameplate and precautionary information furnished 2 Electrical Apparatus of Flame proof Type of Explosion Protected Construction Electrical apparatus which is of flameproof cons...

Page 68: ...B 0202 with no sealing property To protect the apparatus from corrosive gases or moisture apply nonhardening sealant such as liquid gaskets to those threads for waterproofing Specific cables shall be...

Page 69: ...ge the joints or shock the enclosure b If any damage occurs in threads joints or mating surfaces inspection windows connections between the transmitter and terminal box shrouds or clamps or external w...

Page 70: ...Blank Page...

Page 71: ...BRAIN protocol version Except JIS Intrinsically safe type For HART protocol version Except JIS Intrinsically safe type For BRAIN protocol version JIS Intrinsically safe type Optional code JS1 For BRA...

Page 72: ...2 CMPL 1C22A1 01E Subject to change without notice Printed in Japan Blank Page...

Page 73: ...t 1995 Yokogawa Electric Corporation Yokogawa Electric Corporation CMPL 1C22H1 01E 3rd Edition Oct 1999 YK Models EJA118W EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitter Pressur...

Page 74: ...m JIS 40K 3 inch ANSI Class 150 3 inch ANSI Class 300 3 inch ANSI Class 600 3 inch JPI Class 150 3 inch JPI Class 300 3 inch JPI Class 600 50 mm JIS 10K 50 mm JIS 20K 50 mm JIS 40K 2 inch ANSI Class 1...

Page 75: ...3 For PG13 5 and M20 Add Part No to Item 10 For 1 2NPT PG13 5 and M20 Add SUS316 Stainless Steel Part No to Flange material in Table 1 Part No correction made in Table1 Incorrect Correct F9315KA F9351...

Page 76: ...lation and Operating Precautions for JIS Intrinsically Safe and Explosionproof Equipment EX A01E EX A03E EX B01E EX B03E Add Optional code F1 Change a format Change and add Part No of Item 7 1 CPU ass...

Reviews: