IM CL255
19
●Overrange Indication : "OL" is shown on the display
●Response Time : Approx. 2 seconds.
●Sample Rate : Approx. 3 times per second.
● Temperature and Humidity for Guaranteed Accuracy : 23℃ ±5℃ ,
relative humidity up to 75% without condensation
● Operating Temperature and Humidity : 0 to 40℃ , relative humidity up to
85% without condensation
● Storage Temperature and Humidity : -20 to 60℃ , relative humidity up to
85% without condensation
● Effect of conductor position : Within ±1.5%rdg ±3dgt of indicated value
at the center to a 10 mm-dia conductor carrying 100A, at every part
inside the jaws
● Effect of external magnetic field : 4A or less in AC or DC magnetic field
of 400 A/m
● Power Source : 6LR61 or 6F22 9V battery
●Battery Life : Approx. 15 hours (continuity)
●Current Consumption : Approx. 15mA max.
● Sleep function : Automatically powered down in Approx. 30 minutes after
the last switch operation (power consumption : Approx. 200μA)
● Withstanding Voltage : 6300V AC, 50/60Hz for 5sec. between electri-
cal circuit and housing case or metal part of the jaws
● Insulation Resistance : 10MΩ or greater at 1000V between electrical
circuit and housing case or metal part of the jaws
●Conductor Size : Approx. 55mm diameter max.
●Dimensions : Approx. 105(W) x 250(H) x 49(D) mm
●Weight : Approx. 540g (with battery)
●Safety Standard: EN 61010-1, EN 61010-2-033
EN 61010-031, EN 61010-2-032
AC/DC 600V CAT III, AC/DC 1000V CAT II,
Pollution degree 2, indoor use, altitude 2000m or less
●EMC Standard: EN 61326-1, EN 61326-2-1
●Radiation immunity : EN 61000-4-3
●Environmental standard: EN 50581
●Accessories :
Test leads Model 98072
1set
6F22 battery
1
Carrying case Model 93034
1
User s Manual
1
●Optional Accessories : Output cable Model 98076
Output cable (for terminal screw) Model 98077