background image

 

 

User’s 

Manual

 

CL235 
Clamp-on Tester 

クランプテスタ

 

IM CL235

2003.04  

初版

(MC)

 

IM CL235

 

 

Contents 

„

 Precautions for Safety Use of the Instrument --------------------------- i 

1. Instrument Layout ------------------------------------------------------------ 1 
2. Measurement ------------------------------------------------------------------ 3 

2.1 Preparation 

for 

Measurement ------------------------------------------------ 3 

2.2 DC 

Current 

Measurement----------------------------------------------------- 3 

2.3 

AC Current Measurement----------------------------------------------------- 4 

2.4 DC 

Voltage 

Measurement----------------------------------------------------- 5 

2.5 

AC Voltage Measurement ----------------------------------------------------- 5 

2.6 Resistance 

Measurement ----------------------------------------------------- 6 

2.7 

Continuity Check (400

 range fixed)--------------------------------------- 7 

2.8 Frequency 

Measurement------------------------------------------------------ 7 

2.9 Peak 

Measurement ------------------------------------------------------------- 8 

2.10 Average 

Measurement--------------------------------------------------------- 9 

3. Other Functions ------------------------------------------------------------- 10 

3.1 Sleep 

Function ----------------------------------------------------------------- 10 

3.2 

Data Hold Function ----------------------------------------------------------- 10 

3.3 LoHz 

Function------------------------------------------------------------------ 10 

3.4 Optional 

Accessories --------------------------------------------------------- 10 

4. Battery Replacement ------------------------------------------------------ 12 
5. Specifications ---------------------------------------------------------------- 13 
6. Calibration and After-sales Service ------------------------------------ 17 
 
 
 
 

 

IM CL235

 

i

 

„

 Precautions for Safe Use of the Instrument 

When handling the instrument, ALWAYS observe all of the cautionary notes 
on safety given below. Yokogawa M&C Corporation is not at all liable for 
damage resulting from misuse of this product by the user that is contrary to 
these cautionary notes. 
Various symbols are used on the instrument and in this manual to ensure the 
product is used safety and to protect operators and property from possible 
hazards or damage. The following safety symbols are used where appropri-
ate. Read the explanations carefully and familiarize yourself with the symbols 
before reading the text. 
 
The instrument and this manual use the following safety symbols: 

 

Danger! Handle with Care. 

This symbol indicates that the operator must refer to an explanation 
in the User’s Manual in order to avoid the risk of personal injury or
death and/or damage to the instrument. 

 

Double Insulation 

This symbol indicates double insulation. 

 

AC Voltage/Current 

This symbol indicates AC voltage or current. 

 

DC Voltage/Current 

This symbol indicates DC voltage or current. 

 

DC/AC Voltage/Current 

This symbol indicates DC/AC voltage or current. 

 

Ground 

This symbol indicates ground (earth) 

 

WARNING 

Indicates that there is a possibility of serious personal injury or loss of life if 
the operating procedure is not followed correctly and describes the precau-
tions for avoiding such injury or loss of life. 

CAUTION 

Indicates that there is a possibility of serious personal injury of damage to the 
instrument if the operating procedure is not followed correctly and describes 
the precautions for avoiding such injury or damage. 

NOTE 

Draws attention to information essential for understanding the op-

eration and features. 

 

ii 

IM CL235

WARNING

  Never make measurement on a circuit above 600V AC or 600V DC. 

  Do not use the instrument in an atmosphere where any flammable or ex-

plosive gas is present. 

  Do not attempt to make measurement in the presence of flammable gas-

ses, fumes, vapor or dust. Otherwise, the use of the instrument may cause 
sparking, which can lead to an explosion. 

  Avoid using the instrument if it has been exposed to rain or moisture or if 

your hands are wet. 

  Do not exceed the maximum allowabIe input of any measurement range. 

  Never open the battery compartment cover when making measurement. 

  Do not use the instrument if there is any damage to the casing or when the 

casing is removed. 

  Do not turn the Function Selector switch with plugged in test leads con-

nected to the circuit under test. 

  Do not install substitute parts or make any modification to the instrument. 

Return the instrument to Yokogawa M&C or your distributor for repair or 
re-calibration. 

  Always switch off the instrument before opening the battery compartment 

cover for battery replacement. 

 

WARNING

To avoid damage to the instrument or electric shock! 
The restrictions on the maximum voltage level for which the CL235 testers 
can be used, depend on the over-voltage categories specified by the safety 
standards. These category specifications are formulated to protect operators 
against transient impulse voltage in power lines. 
 

Maximum Allowable Input 

Function 

OVERVOLTAGE CATEGORY III 

A, 

AC 600A rms / DC 1000A 

Measuring circuit voltage : AC 600V rms 

                                        DC 600V 

V, 

Input terminal-to-ground voltage 

AC 600V rms/DC 600V 

Over-voltage category I (CAT.I): 

  Signal level, special equipment or parts of equipment, telecommunication, electronic 

etc., with smaller transient over-voltages than CAT.II. 

Over-voltage category II (CAT.II) 

  Local level, appliance, portable equipment etc., with smaller transient over-voltages 

than CAT.III. 

Over-voltage category III (CAT.III): 

  Distribution level, fixed installation, with smaller transient over-voltages than CAT.IV. 

Summary of Contents for CL235

Page 1: ... Indicates that there is a possibility of serious personal injury of damage to the instrument if the operating procedure is not followed correctly and describes the precautions for avoiding such injury or damage NOTE Draws attention to information essential for understanding the op eration and features ii IM CL235 WARNING Never make measurement on a circuit above 600V AC or 600V DC Do not use the ...

Page 2: ...h to the OFF position after use When the instrument will not be in use for a long period of time Place it in storage after removing the battery Use a damp cloth and detergent for cleaning the instrument Do not use abrasives or solvents NOTE Radiation immunity affects the accuracy of CL235 testers under the condi tions specified in IEC801 3 1993 If equipment generating strong electromagnetic interf...

Page 3: ...t WARNING Do not make measurement on a circuit above 600VDC This may cause shock hazard or damage to the instrument or equipment under test Do not make measurement with the test leads plugged into the instrument Correct Wrong 1 Set the Function Selector switch to the A position DC should be shown on the upper left corner of the display 2 With the transformer jaws closed and without clamping them o...

Page 4: ... LCD display 3 With the tip of the test leads shorted together press the button to offset the resistance of the test leads 4 Press the button once to enter from the normal mode to the conti nuity check mode should be indicated on the display 5 Connect the tip of the test leads to the circuit under test If the resistance is 20Ω or less the buzzer beeps 2 8 Frequency Measurement On ACA or ACV range ...

Page 5: ...witched from the normal 3 times sec to 2 times sec to reduce fluctuation of the reading LoHz is also indicated where input is 3 of full scale or less 3 4 Optional Accessories Clamp Adapter Model 99025 For AC current measurement only Clamp Adapter Model 99025 is designed to increase the measuring capability of a clamp meter With the use of the Clamp Adapter you can not only extend current range ove...

Page 6: ... The scales are however actually calibrated in terms of the effective value of a sine wave though the clamp meter is responding to the average value The calibration is done with a conversion factor of 1 111 for sine wave which is found by dividing the effective value by the average value These instruments are therefore in error if the input voltage or current has some other shape than sine wave Wa...

Page 7: ...r still fails to operate correctly and needs repair con tact the vendor from whom you purchased the instrument or the nearest Yokogawa M C sales office Turn off the POWER switch once then turn it back on again If the tester does not turn on replace the battery with a new one Calibration It is recommended that the instrument be calibrated once every year ...

Page 8: ...IA PTY LTD AUSTRALIA Phone 61 2 9805 0699 Facsimile 61 2 9888 1844 YOKOGAWA BLUE STAR LTD INDIA Phone 91 80 227 1513 Facsimile 91 80 227 4270 LTD YOKOGAWA ELECTRIC RUSSIAN FEDERATION Phone 7 095 737 7868 Facsimile 7 095 737 7869 計 測 機 器 営 業 部 180 8750 東京都武蔵野市中町 2 9 32 電話 0422 52 5984 ファクシミリ 0422 55 8953 関 西 支 店 564 0063 大阪府吹田市江坂町 1 23 101 大同生命江坂ビル 10 階 電話 06 6368 7041 ファクシミリ 06 6368 7045 中 部 支 店 4...

Reviews: