YOKOGAWA BA11 Instruction Manual Download Page 5

IM 12B06W03-01E-E

 3

General

•  The BA11 should only be used with 

equipment that meets the relevant EU, 

American, Canadian, and Japanese 

standards. Yokogawa accepts no 

responsibility for the misuse of this unit;

•  The BA11 is packed carefully with shock 

absorbing materials, nevertheless, the 

BA11 may be damaged or broken if 

subjected to strong shock, such as if the 

BA11 is dropped. Please handle with 

care;

•  The BA11 contains devices that can be 

damaged by electrostatic discharge. 

When servicing the BA11, please observe 

proper procedures to prevent such 

damage;

•  Do not use an abrasive or organic solvent 

in cleaning the BA11.

The BA11 is an IEC/EN61326-1 Class A  

product, and it is tested for use in the 

industrial environment.

Specific Conditions of Use

If the BA11 product is not installed using 

Nonincendive Field Wiring, then the BA11 

product shall be installed in compliance 

with the enclosure, mounting, spacing and 

segregation requirements of the ultimate 

application, including a tool removable 

cover.

To maintain the IP66 rating, the BA11 

product shall be installed using the WU11 

cables or the original connector caps 

supplied with the BA11 product.

To maintain the Type 4X rating, the BA11 

product shall be installed using the WU11 

cables or the original connector caps 

supplied with the BA11 product, and the 

BA11 product shall be installed using the 

tool secured, NEMA 4X identified mounting 

bracket which is part of option UM. 

Product Disposal

The instrument should be disposed of 

in accordance with local and national 

legislation/regulations.

1-5. Warning and Disclaimer

The product is provided on an “as is” basis. 

YOKOGAWA shall have neither liability nor 

responsibility to any person or entity with 

respect to any direct or indirect loss or 

damage arising from using the product or 

any defect of the product that YOKOGAWA 

cannot predict in advance.

1-6. Copyright and Trademark Notices

The copyrights of online manual are 

reserved. The online manual is protected 

against modification by the PDF security, 

however 

it can be output via a printer. 

Printing out the online manual is only 

allowed for the purpose of using the 

product. When using the printed information 

of the online manual, check if the version 

read is the most recent one.

Adobe, Acrobat and Acrobat Reader are 

either registered trademarks or trademarks 

of Adobe Systems Incorporated in the 

United States and/or other countries.

All other company and product names 

mentioned in this user’s manual are 

trademarks or registered trademarks of their 

respective companies.

We do not use TM or ® mark to indicate 

those trademarks or registered trademarks 

in this user’s manual. 

Summary of Contents for BA11

Page 1: ...IM 12B06W03 01E E 5th edition Instruction Manual Model BA11 Active Junction Box YOKOGAWA ...

Page 2: ...4 2 2 Regulatory standards 5 2 3 External dimensions and pin assignment of connectors 7 3 Preparation 8 3 1 Installation 8 3 2 Mounting options for BA11 Active Junction Box 8 3 2 1 I nstructions for mounting BA11 on the mounting bracket with or without using the NEMA 4X bracket 8 3 2 2 Instructions for pipe mounting 9 3 2 3 Instructions for wall mounting 10 3 2 4 Instructions for mounting at backs...

Page 3: ...ction 1 1 Unpacking and Checking Upon delivery unpack the BA11 Active Junction Box carefully and inspect it to ensure that it is not damaged during shipment If damage is found retain the original packing material and immediately notify the owner and the relevant local Yokogawa Sales office Make sure the Model Code and Serial Number on the BA11 see figure 1 are the same as on the packing list Also ...

Page 4: ...h Month code January 1 February 2 March 3 April 4 May 5 June 6 July 7 August 8 September 9 October A November B December C 1 4 Safety Precautions In order to protect the system controlled by the product and the product itself and ensure safe operation observe the safety precautions described in this user s manual We accept no liability for safety if users fail to observe these instructions when op...

Page 5: ...using the WU11 cables or the original connector caps supplied with the BA11 product and the BA11 product shall be installed using the tool secured NEMA 4X identified mounting bracket which is part of option UM Product Disposal The instrument should be disposed of in accordance with local and national legislation regulations 1 5 Warning and Disclaimer The product is provided on an as is basis YOKOG...

Page 6: ...s registers read from individual Field Device in time Other IP classification IP66 acc ANSI IEC 60529 2004 C22 2 No 60529 2016 NEMA classification Type 4X acc NEMA 250 2014 ANSI UL 50E 2015 Mechanical Size LxWxH 150 x 64 x 34 mm 5 9 x 2 5 x 1 3 inch Color Grey RAL 7001 Material Aluminium Die Cast housing Applicable torque on cover screw to meet IP66 Min 1 1 Nm Max 2 5 Nm Applicable torque on BA11 ...

Page 7: ...ipment Radio frequency disturbance characteristics Limits and methods of measurement Emission Radiated emission up to 1 GHz SAC LVD Directive By applying 2014 35 EU IEC EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use IEC 61010 2 030 2017 Safety requirements for electrical equipment for measurement control and laboratory use Part 2 030 Particu...

Page 8: ...rt 1 General requirements Certificate no FM19US0166X For Specific conditions of Use refer to section 1 4 FM Canada Nonincendive for Class I Division 2 Groups A B C D Hazardous Classified Location Indoors Outdoors with a Temperature code T6 T5 T4 for 20 C Ta 55 C when connected in accordance with Control Drawing D E 2019 012 A60 By applying CSA C22 2 No 0 4 R2013 Bonding of Electrical Equipment CSA...

Page 9: ...assignment of connectors Figure 2 Dimensions BA11 Active Junction Box WU11 cable pin Male connector Female connectors description 1 Data 2 Data 3 Supply 4 Shield 5 Supply Figure 3 Connection assignment 24 2 52 1 34 34 5 43 1 42 14 Dimension in mm inches BUS IN BUS OUT J1 J4 ...

Page 10: ...ted on a wall pipe or backside of FLXA402 analyzer Mounting materials can be ordered as option UM or as spare part K1548PM In the mounting instructions explained it is a choice to also mount the NEMA 4X bracket 3 2 1 I nstructions for mounting BA11 on the mounting bracket with or without using the NEMA 4X bracket Fasten BA11 base firmly on the mounting bracket using the two M6 screws supplied with...

Page 11: ...cket 3 2 2 Instructions for pipe mounting 14 5 15 2 3 23 1 1 3 31 Dimension in mm inches Figure 6 Pipe mounting Refer to 3 2 1 for bracket mounting Fasten the assembled BA11 together with the bracket on the pipe using M8 U bolt 2x M8 washers and two M8 nuts delivered with UM mounting set ...

Page 12: ...which BA11 is mounted should be strong enough to bear the weight of more than 8 kg 17 64 pound 3 2 4 Instructions for mounting at backside of FLXA402 analyzer Figure 8 Application mounting Refer to 3 2 1 for bracket mounting Fasten the assembled BA11 together with the bracket on the FLXA402 transmitter refer to IM document of the exact model of FLXA402 transmitter for the proper torques at M8 scre...

Page 13: ...rial C Aluminium alloy epoxy coating Type AA General purpose DD Non Incendive for FM US FM Canada Connection type M9 M9 male female connectors 5 pins Options UM Universal mounting set 5 Spare parts Spare part Description K1548DC One set of dust and protection caps K1548PM UM universal mounting set for BA11 ...

Page 14: ...TY FOR DIVISION 2 À L APTITUDE À LA DIVISION 2 5 Cable connectors must be fully engaged using the positioning notch and mechanical retension 6 The BA11 connectors and protection caps must be secured with a torque of 0 25 Nm The lid screws must be secured with a torque of 1 1 Nm 7 Some equipment identifies interconnection parameters using terminology associated with the Zone classification scheme I...

Page 15: ...IM 12B06W03 01E E 13 ...

Page 16: ...Netherlands www yokogawa com eu YOKOGAWA ELECTRIC CORPORATION World Headquarters 9 32 Nakacho 2 chome Musashino shi Tokyo 180 8750 Japan www yokogawa com YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 USA www yokogawa com us YOKOGAWA ELECTRIC ASIA Pte LTD 5 Bedok South Road Singapore 469270 Singapore www yokogawa com sg YOKOGAWA CHINA CO LTD 3F Tower D Cartelo Crocodile Building No 56...

Reviews: