background image

IM 12B06W03-01E-E

 1

Thank you for purchasing the BA11 Active 

Junction Box.

Please read this Instruction Manual carefully 

before installing and using the BA11 Active 

Junction Box.

Please also read the instructions that are 

associated with the sensors and devices 

you are connecting to the junction box. The 

purpose of these user’s manuals is not to 

warrant that the product is well suited to any 

particular purpose but rather to describe the 

functional details of the product. 

No part of the user’s manuals may be 

transferred or reproduced without prior 

written consent from Yokogawa Process 

Analyzers (hereafter simply referred to 

as YOKOGAWA). YOKOGAWA reserves 

the right to make improvements in the 

user’s manuals and product at any time, 

without notice or obligation. If you have 

any questions, or you find mistakes or 

omissions in the user’s manuals, please 

contact our sales representative or your 

local distributor. 

Some drawings may be partially 

emphasized, simplified, or omitted, for the 

convenience of description.

1. Introduction 

1-1. Unpacking and Checking

Upon delivery, unpack the BA11 Active 

Junction Box carefully and inspect it to 

ensure that it is not damaged during 

shipment. If damage is found, retain the 

original packing material and immediately 

notify the owner and the relevant local 

Yokogawa Sales office. Make sure the 

Model Code and Serial Number on the 

BA11 (see figure 1) are the same as on 

the packing list. Also check if option(s) that 

were ordered are included and correct.

1-2. Warranty and Service

Yokogawa products are guaranteed free 

from defects in workmanship and materials 

under normal use and service for a period 

of (typically) 12 months from the date of 

shipment from the manufacturer. Individual 

Sales organizations can deviate from the 

typical warranty period, and the conditions 

of sale relating to the original purchase 

order should be consulted. Damage caused 

by wear and tear, inadequate maintenance, 

corrosion, or by the effects of chemical 

processes is excluded from this warranty 

coverage. In the event of a warranty 

claim, the defective goods should be sent 

(freight paid) to the Service Department 

of the relevant Yokogawa Sales office for 

replacement (at Yokogawa’s discretion).

 1

PREFACE

Figure 1. Example of BA11 product label

Summary of Contents for BA11

Page 1: ...IM 12B06W03 01E E 5th edition Instruction Manual Model BA11 Active Junction Box YOKOGAWA ...

Page 2: ...4 2 2 Regulatory standards 5 2 3 External dimensions and pin assignment of connectors 7 3 Preparation 8 3 1 Installation 8 3 2 Mounting options for BA11 Active Junction Box 8 3 2 1 I nstructions for mounting BA11 on the mounting bracket with or without using the NEMA 4X bracket 8 3 2 2 Instructions for pipe mounting 9 3 2 3 Instructions for wall mounting 10 3 2 4 Instructions for mounting at backs...

Page 3: ...ction 1 1 Unpacking and Checking Upon delivery unpack the BA11 Active Junction Box carefully and inspect it to ensure that it is not damaged during shipment If damage is found retain the original packing material and immediately notify the owner and the relevant local Yokogawa Sales office Make sure the Model Code and Serial Number on the BA11 see figure 1 are the same as on the packing list Also ...

Page 4: ...h Month code January 1 February 2 March 3 April 4 May 5 June 6 July 7 August 8 September 9 October A November B December C 1 4 Safety Precautions In order to protect the system controlled by the product and the product itself and ensure safe operation observe the safety precautions described in this user s manual We accept no liability for safety if users fail to observe these instructions when op...

Page 5: ...using the WU11 cables or the original connector caps supplied with the BA11 product and the BA11 product shall be installed using the tool secured NEMA 4X identified mounting bracket which is part of option UM Product Disposal The instrument should be disposed of in accordance with local and national legislation regulations 1 5 Warning and Disclaimer The product is provided on an as is basis YOKOG...

Page 6: ...s registers read from individual Field Device in time Other IP classification IP66 acc ANSI IEC 60529 2004 C22 2 No 60529 2016 NEMA classification Type 4X acc NEMA 250 2014 ANSI UL 50E 2015 Mechanical Size LxWxH 150 x 64 x 34 mm 5 9 x 2 5 x 1 3 inch Color Grey RAL 7001 Material Aluminium Die Cast housing Applicable torque on cover screw to meet IP66 Min 1 1 Nm Max 2 5 Nm Applicable torque on BA11 ...

Page 7: ...ipment Radio frequency disturbance characteristics Limits and methods of measurement Emission Radiated emission up to 1 GHz SAC LVD Directive By applying 2014 35 EU IEC EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use IEC 61010 2 030 2017 Safety requirements for electrical equipment for measurement control and laboratory use Part 2 030 Particu...

Page 8: ...rt 1 General requirements Certificate no FM19US0166X For Specific conditions of Use refer to section 1 4 FM Canada Nonincendive for Class I Division 2 Groups A B C D Hazardous Classified Location Indoors Outdoors with a Temperature code T6 T5 T4 for 20 C Ta 55 C when connected in accordance with Control Drawing D E 2019 012 A60 By applying CSA C22 2 No 0 4 R2013 Bonding of Electrical Equipment CSA...

Page 9: ...assignment of connectors Figure 2 Dimensions BA11 Active Junction Box WU11 cable pin Male connector Female connectors description 1 Data 2 Data 3 Supply 4 Shield 5 Supply Figure 3 Connection assignment 24 2 52 1 34 34 5 43 1 42 14 Dimension in mm inches BUS IN BUS OUT J1 J4 ...

Page 10: ...ted on a wall pipe or backside of FLXA402 analyzer Mounting materials can be ordered as option UM or as spare part K1548PM In the mounting instructions explained it is a choice to also mount the NEMA 4X bracket 3 2 1 I nstructions for mounting BA11 on the mounting bracket with or without using the NEMA 4X bracket Fasten BA11 base firmly on the mounting bracket using the two M6 screws supplied with...

Page 11: ...cket 3 2 2 Instructions for pipe mounting 14 5 15 2 3 23 1 1 3 31 Dimension in mm inches Figure 6 Pipe mounting Refer to 3 2 1 for bracket mounting Fasten the assembled BA11 together with the bracket on the pipe using M8 U bolt 2x M8 washers and two M8 nuts delivered with UM mounting set ...

Page 12: ...which BA11 is mounted should be strong enough to bear the weight of more than 8 kg 17 64 pound 3 2 4 Instructions for mounting at backside of FLXA402 analyzer Figure 8 Application mounting Refer to 3 2 1 for bracket mounting Fasten the assembled BA11 together with the bracket on the FLXA402 transmitter refer to IM document of the exact model of FLXA402 transmitter for the proper torques at M8 scre...

Page 13: ...rial C Aluminium alloy epoxy coating Type AA General purpose DD Non Incendive for FM US FM Canada Connection type M9 M9 male female connectors 5 pins Options UM Universal mounting set 5 Spare parts Spare part Description K1548DC One set of dust and protection caps K1548PM UM universal mounting set for BA11 ...

Page 14: ...TY FOR DIVISION 2 À L APTITUDE À LA DIVISION 2 5 Cable connectors must be fully engaged using the positioning notch and mechanical retension 6 The BA11 connectors and protection caps must be secured with a torque of 0 25 Nm The lid screws must be secured with a torque of 1 1 Nm 7 Some equipment identifies interconnection parameters using terminology associated with the Zone classification scheme I...

Page 15: ...IM 12B06W03 01E E 13 ...

Page 16: ...Netherlands www yokogawa com eu YOKOGAWA ELECTRIC CORPORATION World Headquarters 9 32 Nakacho 2 chome Musashino shi Tokyo 180 8750 Japan www yokogawa com YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 USA www yokogawa com us YOKOGAWA ELECTRIC ASIA Pte LTD 5 Bedok South Road Singapore 469270 Singapore www yokogawa com sg YOKOGAWA CHINA CO LTD 3F Tower D Cartelo Crocodile Building No 56...