F²MC-16LX Family, Flash Programmer Yokogawa AF220/221
www.cypress.com
Document No. 002-05108 Rev. *B
11
Note:
For minimum configuration at least the signals GND(GND), TRXD(SOTx), TTXD(SINx), TCK(SCKx), /TRES(/RST)
and TVCC(VCC) have to be connected. The other MCU signals can be set static to their levels: MD0=P00=GND,
MD1=MD2=P01=Vcc while programming.
3
Stand-alone operation
This chapter describes the Yokogawa Flash-Programmer in stand-alone mode.
The Yokogawa Flash-programmer can be used as stand-alone programmer. In this case, the programmer can be
controlled by the integrated keypad.
The basic functions are listed below.
Note that an explicit connect-command does not exist.
Table 3. Basic Functions in stand-alone mode
Function
Key-code
Load HEX-file
[FUNC] F 1
/
[SET] [FUNC] [SET]
Blank Check
[DEV] 9 [SET] [DEV] [SET]
Erase (including blank-check)
[DEV] C [SET] [DEV] [SET]
Program
[DEV] D [SET] [DEV] [SET]
Read Check (Verify)
[DEV] E [SET] [DEV] [SET]
Automatic (Erase, Program, Verify)
[DEV] F [SET] [DEV] [SET]
Save HEX-file
[FUNC] F 2
/
[SET] [FUNC] [SET]
Purge file
[FUNC] F 3
/
[SET] [FUNC] [SET] [SET]
For further and more specific functions, please refer to the Instruction Manual of the Yokogawa Flash-programmer.