<5. Basic Operating Procedures>
50
IM 01E24A01-01EN
(3) Display Line Setting
Display Menu Path:
Device setup ► Detailed setup ► Display set ► Optional config ►
Line mode
Available to select the number of lines of process value to
be indicated on the display.
Up to four lines can be displayed at the same time. The
character size changes depending on the number of line.
Setting item
Contents
1 line(big)
Number of displayable process value : One (without
unit)
1 line
Number of displayable process value : One (with unit)
2 line
Number of displayable process values : Two
3 line
Number of displayable process values : Three
4 line
Number of displayable process values : Four
Table 5.2.3 Display line setting and display example
Lines of
display
Example 1
Example 2
1 line(big)
F0503.ai
0.50000
00
:
00
VEL
SET
SFT
INC
F0508.ai
00
:
00
FNL
SET
SFT
INC
* Not indicate the Flow noise
status.
* Indicate 32 characters of the
Long Tag.
1 line
F0504.ai
0.50000
00
:
00
VEL
SET
SFT
INC
m/s
F0509.ai
00
:
00
FNL
SET
SFT
INC
Normal
* Indicate 32 characters of the
Long Tag.
2 line
F0505.ai
0.5000
50.0
m/s
%
00
:
00
VEL
SET
SFT
INC
FLP
F0510.ai
00
:
00
FNL
SET
SFT
INC
Normal
Long tag 1234567
89ABCDEFGabcdefg
LTG
* Indicate 32 characters of the
Long Tag.
3 line
F0506.ai
0.50000
50.0
12.00
m/s
%
mA
00
:
00
VEL
FLP
AO1
SET
SFT
INC
F0511.ai
00
:
00
FNL
SET
SFT
INC
Normal
Long tag 1234567...
TAG12345
LTG
TAG
* Indicate 32 characters of the
Long Tag in the first line.
* Indicate 16 characters in the
first half of 32 characters of the
Long Tag in the second and
third lines.
4 line
F0507.ai
0.50000
50.0
12.000
m/s
%
mA
Normal
00
:
00
VEL
AO1
FNL
SET
SFT
INC
FLP
F0512.ai
00
:
00
FNL
SET
SFT
INC
Normal
Long tag 1234567...
TAG12345
LTG
TAG
* Indicate 16 characters in the
first half of 32 characters of the
Long Tag only
(4) Date Display Formant Setting
Display Menu Path:
Device setup ► Detailed setup ► Display set ► Optional config ►
Format date
The date display format can be specified below.
Setting item
Contents
MM/DD/YYYY
Displays the date in "month/day/year".
DD/MM/YYYY
Displays the date in "day/month/year".
YYYY/MM/DD
Displays the date in "year/month/day".
The date needs to be set every time when the power is
turned on.
In case the date is not set:
• BRAIN communication: Date counting starts from the
date stored in the memory.
• HART communication: Date counting starts
from 1900/01/01 00:00:00, according to HART
specification.
(5) Inverse Display Setting
Display Menu Path:
Device setup ► Detailed setup ► Display set ► Optional config ►
Inversion
Available to change from normal diplay to white/black
reverse display.
Setting item
Contents
Normal
Characters in the display is Black.
Inverse
Outline characters