9
AC Current Measurement
A
734 01
Range
Accuracy
Maximum
Input Current
Resolution
500
µ
A
5000
µ
A
50mA
500mA
5A
10A
0.01
µ
A
0.1
µ
A
0.001mA
0.01mA
0.0001A
0.001A
1.5+20
1+20
500mA
Protected by a
500mA/600V
fuse.
15A
Protected by a
15A/600V fuse.
<0.11
mV/
µ
A
<4mV/mA
<0.1V/A
Voltage Drop
10 to 20Hz 20Hz to 1kHz
Crest factor: <3
AC Current Measurement
A
734 02
Accuracy
Resolution
Range
1k to
5kHz
20Hz to
1kHz
10 to
20Hz
Voltage
Drop
Maximum
Input Current
0.01
µ
A
0.1
µ
A
0.001mA
0.01mA
0.0001A
0.001A
500
µ
A
5000
µ
A
50mA
500mA
5A
10A
1+20
0.75
+20
1+30
1.5+20
1+20
2+30
<0.11
mV/
µ
A
500mA
Protected by a
500mA/600V
fuse.
15A
Protected by a
15A/600V fuse.
<4
mV/mA
<0.1
V/A
Crest factor: <3
Model 734 01/02
Accuracy
At 5 to 100% of range
Note: At 10 to 100% of range for 10A Range
Response time: 2 sec max.