IM 2793-01E

― iii ―

■ Since mishandling the instrument can result in an accident that may lead to injury or 

 

death of the operator, such as an electric shock, be sure to observe the following instructions.

WARNING

 

● Measurement

• Always maintain the instrument within the limits for allowable current, voltage and power, during operation.

  If there is more than one limit for any of these parameters, the lowest limit takes precedence.

• Only operate the instrument on an input-to-ground supply voltage of no greater than 250 V 

 

(except for Model 279303).

• When an input-to-ground supply voltage of greater than 250 V needs to be applied to Model 279303, 

 

exercise extra care when handling the instrument.

• The terminals and internal circuitry may become electrified to high voltages and extremely hot depending on 

 

the instrument’s condition of use. Do not touch these parts.

● Grounding

• To avoid electric shock, be sure to apply protective grounding to the grounding terminal.

● Protective Measures

• If a crack appears in the instrument after it has been accidentally dropped or bumped, 

 

the safety-purpose insulation may be damaged.

  By all means do not use the instrument, but ask the manufacturer for repair.

● Operating Environment

• Do not operate the instrument in a flammable or explosive gas atmosphere.
• Do not operate the instrument if there is any condensation on it.

● Do Not Remove the Casing or Disassemble

• Only Yokogawa service personnel are authorized to remove the casing or disassemble or 

 

modify the instrument.

  Do not attempt to repair the instrument yourself, as doing so is extremely dangerous.

  (If you are rack-mounting the instrument, use it correctly according to the handling procedure.)

Summary of Contents for 279301

Page 1: ...2793 279301 279303 Decade Resistance Box User s Manual IM 2793 01E IM 2793 01E 8th Edition Oct 2017 YMI...

Page 2: ...ntact information of Yokogawa offices worldwide is provided on the following sheet PIM 113 01Z2 Inquiries List of worldwide contacts Notes The information contained in this manual is subject to change...

Page 3: ...use of the instrument in contradiction to these cautionary notes The following safety symbols are used on the instrument and in the manual Danger Handle with Care This symbol indicates that the opera...

Page 4: ...ectrified to high voltages and extremely hot depending on the instrument s condition of use Do not touch these parts Grounding To avoid electric shock be sure to apply protective grounding to the grou...

Page 5: ...se of the Product ii 1 GENERAL 1 2 NAMES AND FUNCTIONS OF COMPONENTS 1 3 SPECIFICATIONS 2 4 CIRCUIT DIAGRAM 3 Disposing the Product 4 8th Edition October 2017 All Rights Reserved Copyright 1991 Yokoga...

Page 6: ...01 It is best suited for calibration of resistance thermometers The 279303 has resistance range of 0 to 111 1110 M in 100 steps and accuracy of 0 05 It is best suited for calibration of insulation re...

Page 7: ...g T C of wiring and switches resistance 60 C 100 step 10 step 1 step 0 1 step 50 mA 150 mA 500 mA 1 5 A Resistance Range Dial Composition Accuracy 0 to 111 1110 M 100 10 1 k 10 10 k 10 100 k 10 1 M 10...

Page 8: ...am 279301 S6 S5 S4 S3 S2 S1 R104 1000 R105 1000 R103 200 R102 200 R101 100 R601 R602 R603 R604 R605 R606 R607 R608 R609 R610 100 R501 R502 R503 R504 R505 R506 R507 R508 R509 R510 1 k R401 R402 R403 R4...

Page 9: ...ement This marking indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE directive this...

Page 10: ...Printed in Japan...

Reviews: