YMGI MINI SPLIT TYPE User Manual Download Page 9

P16 OF 24

Subject to Continuous Engineering Improvement without Prior Notice.

P15 OF 24

Subject to Continuous Engineering Improvement without Prior Notice.

FUNCTIONS-REMOTE OR LINE CONTROLLER

Display Signs:

1.Once powered on, displays indoor temperature at idle status; displays set temperature during setting 
   temperatures in COOLING mode and HEATING mode; displays indoor temperature at other modes or 
   circumstances.
2.At TIMER ON or OFF, other than TIMER sign is lit, SLEEP, COOLING, or HEATING sign will be lit, if set up 
   TIMER ON or OFF for.
3.When unit is in operation, LED lit up once the corresponding function is clicked on: COOLING, 
   DUHUMIDIFICATION, FAN and HEAT.
4.Fan speed is told by the speed of the FAN sign blade spinning. At fan stopping, FAN sign blade stops spinning; 
   At DEFROST during HEAT mode, FAN sign blade stops spinning.
5.Error signs

FAILURE

Indoor temperature

sensor failure

Indoor coil tube

temperature sensor failure

TIMER/SLEEP LED

Lit

Lit

OPERATION LED

Blinks, 2 Times/8 Secs.

Blinks, 3 Times/8 Secs.

CENTER DISPLAY

E2

E3

Remarks: 

1.Blink: lit for 0.5 sec., then off for 0.5 sec., then lit for 0.5 sec
2.E4 Code:
* Outdoor ambient temperature is too low (user remembers not to run unit during severe cold weather).
* Refrigerant at low level (users need to call service contractor to check unit).

Lit

Blinks, 4 Times/8 Secs.

E4

System runs out of 

preferred design ranges

LED DISPLAY PANEL

REPARATING REMOTE OR LINE CONTROLER

Short-circuit RESET button as indicated (after the
change of the batteries).

Open the lid at back, place the 2 AAA 1.5V-LR03 
batteries in right polarities.

NOTICE

If the remote controller does not operate 
correctly, press RESET button to resolve it.

The signal can be transmitted as far as 275 
inches (7 meters) away from the indoor unit if 
the controller is pointed towards the front of 
the indoor unit.

Take care of the remote/line controller. To 
avoid any problem, do not drop it on the floor 
or throw it or expose it at the humidity.

When press a button, the indoor unit beeps 
once or twice, indicating the indoor unit has 
received control signal.

Remove the batteries if you don't use the remote/line 
controller for a long period.

A.Power

BATTERY ON/OFF

Once two AAA batteries are loaded into the remote controller battery compartment in the right polarity, LCD 
screen shows all signs available for 3 seconds before they all go off the screen totally. 

Once one or two batteries are unloaded from the remote controller battery compartment, if no button is 
touched, the LCD screen display will go off in 15 seconds, if any button is pressed within 15 seconds, the LCD 
screen display will go off right away.

B.Run / Stop

"ON/OFF"

If ON/OFF button is pressed the first time, LCD displays AUTO, temperature meter sign, AUTO FAN and 
SWING from the top to bottom of the LCD screen;

If ON/OFF button is pressed after power off, LCD displays what is left prior to POWER OFF (including MODE, 
TEMPERATURE, FAN SPEED, LOUVER, but excluding SLEEP, TIMER and FRESH).

ON/OFF

C.Temperature/Time Adjustment

These buttons are for time adjustment too. If pressed intermittently within 5 seconds after pressing TIMER ON 
or TIMER OFF, time (hour) changes at 1hour/press; if held down continuously, time changes at 1hour/0.5Sec. 
Time cycle is between 1-12hrs. 

Temparature/Time change will show up on the Controller's LCD display. 

Temperature range is 64 to 86F, Time range is 0 to 24Hr or 0 to 12Hr.

Normally, these buttons are for temperature up and down adjustment at 1F/press, to decrease 1F, press "    " 
button once; to increase 1F, press "

"button once; If held down for continuous adjustment, number changes at 

1F/0.5Sec. 

(auto)

(high)

D.Fan Speed Adjustment

FAN

(medium)

(low)

FAN MODE includes: AUTO, LOW, MED and HIGH. Every time  FAN

 button is pressed once, fan sign 

changes once from one to the next one in a sequence: LOW (1-section/fan blade spins slowly), MED. (3-section/ 
fan blade spins a little quicker), HIGH (5-section/fan blade spins quicker), AUTO (4-blade fan).

E. "FRESH" 

FRESH

F.

SLEEP

SLEEP

Press "SLEEP" button to turn the unit into or out of SLEEP mode. When SLEEP button is pressed, star/moon 
sign either shows up or goes off. If star/moon sign is ON, MODE turns into SLEEP mode (see related function 
change separately); if pressed again, star/moon sign goes off, MODE turns into the regular. 

Otherwise claimed, this button is not actuated for:
* Fresh air, or,
* Manual turn on or off supplemental heating

Summary of Contents for MINI SPLIT TYPE

Page 1: ...manufactured free from defects in material and workmanship under the normal use and maintenance Installation operation maintenance and service shall follow professional practices for regular cooling a...

Page 2: ...echnician Customers must NOT Install This Unit by Themselves or Hire Non Licensed Persons to Do the Job We Decline Any Consequences Including Damage to Unit People Properties and Others Resulted from...

Page 3: ...ical power is disconnected from the unit by making a notice or put a sign at the power switch panel to keep other people from setting the power back during installation Connect all wiring securely Any...

Page 4: ...o the Undersized or Oversized Unit Selection Improper Design Incorrect Unit Anticipation and the sort IMPORTANT NOTES AGAIN YMGI IS NOT AND SHALL NOT BE RESPONSIBLE FOR Under performance or damage to...

Page 5: ...moment to refresh the atmosphere Do NOT use the unit in cool dry during a prolonged period at high moisture higher than 80 Condensation could be formed on the indoor unit casing if a door or window is...

Page 6: ...cating Lamp Signal Receiving Window Emergency Switch Horizontal Louver Power Plug Vertical Louver Air Outlet Air Filter Remote Controller Air Inlet Connecting Pipe and Cable Drainage Hose Air Outlet O...

Page 7: ...ovement without Prior Notice COMPONENTS MULTI ZONE SAMPLE DUAL ZONE OVER 500mm 20 Outdoor unit OVER 50mm 2 OVER 100mm 4 OVER 2000mm 80 Indoor unit A OVER 100mm 4 Indoor unit B COMPONENTS MULTI ZONE SA...

Page 8: ...Set temperature Status indicating bar 2 bar indicator POWER ON Cooling mode Timer mode Fast cooling Auxiliary electrical heating Status indicating bar 4 bar indicator Room temperature reachs to setti...

Page 9: ...the batteries if you don t use the remote line controller for a long period A Power BATTERY ON OFF Once two AAA batteries are loaded into the remote controller battery compartment in the right polari...

Page 10: ...ge operation mode as the room temperature changes If unit restarts after last operation stops for two hours it will start in the same mode as set before operation was stopped Press SWING button to cha...

Page 11: ...T MODE Pointing remote line controller to the unit press MODE button until HEAT is shown In this mode you can press FAN SPEED button to change the fan speed of indoor unit Press TEMPERATURE ADJUSTMENT...

Page 12: ...the installer or distributor Unit does not operate at all Remote controller does not display Cooling and heating is not satisfied after running for a long time Blower doesn t run while outdoor unit i...

Page 13: ...el due to temperature changes at unit startup or shutdown During cooling condensate from pipes or coils accumulated During heating condensate at heat exchanger coil drips During heating at defrosting...

Page 14: ...AL TECHNICAL QUESTIONS OR SUPPORT 1 The original installer otherwise 2 The current service contractor otherwise 3 The nearest distributor otherwise 4 YMGI Technical Support Tel 866 833 3138 703 Email...

Page 15: ...r phenomenon you have seen as a unit history No Date Service Maintenance Conducted Person Phone USER NOTES Put down whatever questions you have or phenomenon you have seen as a unit history No Date Qu...

Page 16: ......

Reviews: