INST
ALLER'S
INSTRUCTION
P16 OF 38
INSTALL INDOOR UNIT
INSTALL THE REAR PANEL
1) Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the both-way
drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the
outlet of the water tray as the center of a circle, the included angle between the evaporator and level should be
0 or more, that is good for condensing water drainage.
2) Fix the rear panel on the wall with screws.(Where is pre-covered with plastic granula)
3) Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 60kg, further
more, the weight should be evenly shared by each screw.
INSTALL THE PIPING HOLE
1) Make the piping hole (U55) in the wall at a slight downward slant to the outdoor
side.
2) Insert the piping-hole sleeve into the hole to prevent the connection piping and
wiring from being damaged when passing through the hole.
INSTALL THE WATER DRAINAGE PIPE
1) For well draining, the drain hose should be placed
at a downward slant.
2) Do not wrench or bend the drain hose or flood its
end by water.
3) When the long drainage hose passing through
indoor, should wrap the insulation materials.
Space
to the
wall
5.9 inch
above
Space
to the
wall
5.9 inch
above
2.17
inch
CONNECT INDOOR AND OUTDOOR ELECTRIC WIRES
1) Open the surface panel.
2) Remove the wiring cover Fig 6.
3) Route the power connection cord and signal
control wire (for cooling and heating unit only) from
the back of the indoor unit and pull it toward the
front through the wiring hole for connection.
4) Reassemble the clampand wiring cover.
5) Recover the surface panel.
Indoor
Outdoor
Seal pad
Wall pipe
Wiring Cover
L1
L2
S
BN
BU
BK YEGN
Outdoor unit
connection
Wrenched
Bet
Flooded
Wall
Mark on the middle of it
Gradienter
Wall
Left
0.2 inch
(Rear piping hole)
Right
0.2 inch
(Rear piping hole)
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !
INST
ALLER'S
INSTRUCTION
P15 OF 38
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !
INSTALLATION DIMENSION DIAGRAM
OVER 20"
OVER 10"
OVER 10"
OVER 8"
OVER 10"
Indoor unit A
OVER 2"
OVER 4"
OVER 4"
OVER 80"