Yingli Solar PV Modules, Installation and User Manual 

page 2

De-energize PV modules by removing them entirely from light or by

 

covering 

their front surface with an opaque material. Regard the safety regulations for 
live electrical equipment when working with modules that are exposed to any 
light. Use insulated tools and do not wear metallic

 

jewelry while working with 

PV modules.

In order to avoid arcing and electrical shock, do not disconnect electrical 
connections under load. Faulty connections can also result in arcing and 
electrical shock. Keep connectors dry and clean, and ensure that they are in 
proper working condition. Never insert metallic objects into the connectors, or 
modify them in any way in order to secure an electrical connection.

Do not touch or handle PV modules with broken glass, separated frames or 
a damaged backsheet unless the PV modules are first disconnected and you 
are wearing proper PPE. Avoid handling PV modules when they are wet unless 
cleaning the PV modules as directed in this manual. Never touch electrical 
connections that are wet without protecting yourself with insulated gloves.

Transport and Handling

Yingli Solar PV modules must be transported in the supplied packaging only and 
kept in the packaging until they are ready to be installed. Protect pallets against 
movement and exposure to damage during transportation. Secure pallets from 
falling over. Do not exceed the maximum height of pallets to be stacked, as 
indicated on the pallet packaging. Store pallets in a cool and dry location until 
the PV modules are ready to be unpackaged.

Figure 2: Pallet of PV modules

Yingli Solar PV modules are heavy, and should be handled with care. PV modules 
shall be handled at the frame; never use the junction box or cables as a grip. Do 
not exert mechanical stress on the cables. Never step on PV modules or drop 
or place heavy objects on them. Be careful when placing PV modules on hard 
surfaces, and secure them from falling. Broken glass can result in personal injury. 
PV modules with broken glass cannot be repaired and must not be used. Broken 
or damaged PV modules must be handled carefully and disposed of properly.

For unpacking PV modules from the Yingli Solar supplied packaging, first remove 
the pallet lid (after removing securing straps, if provided). Remove PV modules 
one at a time by sliding them up the channel in the package (see Figure 3). You 
may need to secure the remaining PV modules in the pallet packaging to prevent 
them from falling over. 

 
 

Figure 3: Removing PV modules from a pallet

Check PV modules for damage due to transportation before they are installed; 
do not install damaged modules. Contact the company you purchased the Yingli 

Solar PV modules from in order to obtain information on making claims for 
defective PV modules. 

PV module surfaces are susceptible to damage that could affect the performance 
or safety of the PV module; do not damage or scratch the PV module surfaces, 
and do not apply paint or adhesive to any of the surfaces, including the frame. 
For your safety, do not disassemble or modify Yingli Solar PV modules in any 
way. Doing so may degrade performance or cause irreparable damage and will 
void any applicable warranties. 

If it is necessary to store PV modules prior to installation, the PV modules 
should remain inside the packaging and protected from exposure that could 
compromise the durability of the packaging. 

Fire

Yingli Solar PV Modules have a Class C fire resistance rating in accordance with 
the IEC 61730-2 certification. When PV modules are mounted on rooftops, the 
roof must have a fire resistant covering suitable for this application. PV modules 
are electrical generating devices that may affect the fire safety of a building.

The use of improper installation methods and/or defective parts may result 
in the unexpected occurrence of an electrical arc during operation. In order to 
mitigate the risk of fire in this event, PV modules should not be installed near 
flammable liquids, gases, or locations with hazardous materials. 

In the event of a fire, PV modules may continue to produce a dangerous voltage, 
even if they have been disconnected from the inverter, have been partly or 
entirely destroyed, or the system wiring has been compromised or destroyed. In 
the event of fire, inform the fire crew about the particular hazards from the PV 
system, and stay away from all elements of the PV system during and after a fire 
until the necessary steps have been taken to make the PV system safe.

A P P L I C AT I O N   I N F O R M AT I O N

Application Restrictions

Yingli Solar PV modules must be mounted on appropriate mounting structures 
positioned on suitable buildings, the ground, or other structures suitable for PV 
modules (e.g. carports, building facades or PV trackers). PV modules must not 
be mounted on moving vehicles of any kind. Yingli Solar PV modules must not 
be installed in locations where they could be submerged in water. 

Yingli Solar PV modules must not be sited in locations where aggressive 
substances such as salt or salt-water, or any other type of corrosive agent, could 
affect the safety and/or performance of the PV modules. Although some types 
of Yingli Solar PV modules have passed the IEC 61701 salt-mist corrosion test 
with a salt concentration of 5% by weight, galvanic corrosion can occur between 
the aluminum frame of the PV module and mounting or grounding hardware if 
such hardware is comprised of dissimilar metals. Yingli Solar recommends that 
only stainless steel and aluminum metal directly contact PV modules in seaside 
installations to limit corrosion. 

Artificially concentrated light must not be directed on Yingli Solar PV modules. 

Design Recommendations

Yingli Solar recommends that PV modules be mounted at a minimum tilt angle 
of 10 degrees to allow for proper self-cleaning from normal rain showers.

Partial or complete shading of a PV module or modules can significantly reduce 
system performance. Yingli Solar recommends minimizing the amount of shade 
throughout the year to increase the amount of energy produced by the PV 
modules.

Lightning protection is recommended for PV systems that are to be installed in 
locations with high probability of lightning strikes.

High system voltages could be induced in the event of an indirect

 

lightning 

strike, which could cause damage to PV system components.

 

The open area of 

wire loops should be minimized, as shown in Figure 4,

 

in order to reduce the risk 

Summary of Contents for YL250P-29b

Page 1: ...ication laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the English language version shall control Failure to comply with the...

Page 2: ...g so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the pa...

Page 3: ...Series wiring voltage additive Parallel wiring current additive Fully engage and lock Cap...

Page 4: ...at a designated grounding hole location using only stainless steel hardware Insert an M5 stainless steel screw first through the stainless steel cup washer and then through the grounding hole 2 Loosel...

Page 5: ...Landscape Orientation Portrait Orientation Screw Backing Nut Nut Washer PV Laminate Mounting Rail Aluminum Frame...

Page 6: ...al installation The PV system can generate hazardous voltage even after the system has been disconnected Follow safety regulations for working with live electrical equipment R ecycling Yingli Solar is...

Page 7: ...b YL280C 30b YL330C 36b YL235D 25b YL280D 30b YL335D 36b YL275P 29b YL325P 35b YL245C 25b YL285C 30b YL335C 36b YL240D 25b YL285D 30b YL340D 36b YL280P 29b YL330P 35b YL250C 25b YL290C 30b YL340C 36b...

Page 8: ...5 31 0 8 90 1000 15 YL270P 29b 270 37 9 9 27 30 7 8 80 1000 15 YL265P 29b 265 30 5 8 70 37 8 9 18 1000 15 YL260P 29b 260 30 3 8 59 37 7 9 09 1000 15 YL255P 29b 255 30 0 8 49 37 7 9 01 1000 15 YL250P 2...

Page 9: ...5 YL330D 36b 330 37 2 8 86 46 6 9 29 1000 15 YL325D 36b 325 36 9 8 81 46 2 9 27 1000 15 YL320D 36b 320 36 6 8 75 45 9 9 24 1000 15 YL315D 36b 315 36 2 8 69 45 5 9 21 1000 15 YLM 60 Cell 40mm Series YL...

Page 10: ...age 10 REA R AND S IDE VIE W DIMENS IONS OF MODULE SE RIES with 50mm frame UNITS mm PANDA 72 Cell NH Series Frame Cross Section 12 32 50 SECTION A A Frame P Cross Section A A Legend Legend Grounding h...

Page 11: ...Series also valid for YLM 72Cell 40mm Series REA R AND S IDE VIE W DIME NSIONS OF MODULE SER IES with 40mm frame CONT UNITS mm 1100 946 990 1960 150 55 A A 403 40 1960 577 577 Grounding holes 8 6 Moun...

Page 12: ...IDE VIEW D IME NSIONS OF M ODULE SER IES with 35mm frame UNITS mm 1000 946 990 967 1640 150 55 Drainage holes 8 3 8 Mounting holes 4 6 5 8 Grounding holes 8 6 A A 336 5 35 1640 100 100 100 100 Legend...

Reviews: