Yingli Solar PV Modules, Installation and User Manual 

page 8

This supplement refers to modules of the follwing types:

FAMILY

YGE 60 Cell SERIES

&

YGE-Z 60 Cell SERIES

YGE 72 Cell SERIES

YGE 72 Cell NH SERIES

PANDA 48 Cell SERIES

PANDA 60 Cell SERIES

TYPE

YL230P-29b

YL280P-35b

YL180C-24b

YL225C-30b

YL235P-29b

YL285P-35b

YL185C-24b

YL230C-30b

YL240P-29b

YL290P-35b

YL190C-24b

YL235C-30b

YL245P-29b

YL295P-35b

YL195C-24b

YL240C-30b

YL250P-29b

YL300P-35b

YL200C-24b

YL245C-30b

YL255P-29b

YL305P-35b

YL205C-24b

YL250C-30b

YL260P-29b

YL310P-35b

YL210C-24b

YL255C-30b

YL265P-29b

YL315P-35b

YL215C-24b

YL260C-30b

YL265C-30b

YL270C-30b

M O U N T I N G   R E Q U I R E M E N T S

Mounting Method Option A: Bolts or clamps

Modules that Require       

Four (4) Connection Points

The Following Modules Require Six (6) Con-

nection Points for Installations that Exceed 50 

psf (2400 Pa) Loading

YGE 60 Cell SERIES & YGE-Z 60 Cell 

SERIES

YGE 72 Cell NH SERIES

YGE 72 Cell SERIES*

PANDA 60 Cell SERIES & PANDA 60 

Cell SERIES

* Connections are required at the four outer mounting holes

E L E C T R I C A L   C H A R AC T E R I S T I C S

Nameplate ratings are average values. The electrical characteristics are /- 10 percent of the indicated values of Isc, Voc, and Pmax under Standard Test 

Conditions (irradiance of 1000 W/m2, AM 1.5 spectrum, and a cell temperature of 25ºC). Refer to module datasheets for specific power output tolerance.

Module  

family

Module  

type

Power  

output

Voltage at  

Pmax

Current at  

Pmax

Open-circuit voltage

Short-circuit current

Max. DC system 

voltage

Max. series fuse 

rating

P

max

V

mpp

I

mpp

V

oc

I

sc

[W]

[V]

[A]

[V]

[A]

[V]

[A]

YGE 60  Cell 

SERIES&YGE-Z 60 

Cell SERIES 

 

YL265P-29b

265

30.5 

8.70 

37.8 

9.18

1000

15

YL260P-29b

260

30.3 

8.59 

37.7 

9.09

1000

15

YL255P-29b

255

30.0 

8.49 

37.7 

9.01

1000

15

YL250P-29b

250

29.8 

8.39 

37.6 

8.92

1000

15

YL245P-29b

245

29.6 

8.28 

37.5 

8.83

1000

15

YL240P-29b

240

29.3 

8.18 

37.5 

8.75

1000

15

YL235P-29b

235

29.1

8.08 

37.4

8.66

1000

15

YL230P-29b

230

28.9

7.97

37.3

8.57

1000

15

YGE 72 Cell  

NH SERIES

YL315P-35b

315

36.8

8.56 

45.7

9.12

1000

15

YL310P-35b

310

36.3 

8.53 

45.6 

8.99

1000

15

YL305P-35b

305

36.1 

8.45 

45.4 

8.93

1000

15

YL300P-35b

300

35.8 

8.37 

45.2 

8.86

1000

15

YL295P-35b

295

35.6 

8.29 

45.0 

8.79

1000

15

YL290P-35b

290

35.3 

8.22 

44.8 

8.73

1000

15

YL285P-35b

285

35.0 

8.14 

44.6 

8.66

1000

15

YL280P-35b

280

34.7 

8.06 

44.4 

8.59

1000

15

 

Module Supplement

YINGLI SOLAR

Installation Method: Zep Solar Mounting Systems

 ZSI, ZSII

YGE-Z 60 Cell SERIES*

* Refer to “YGE-Z Series Installation Supplement” for additional information

Summary of Contents for PANDA 48 Cell Series

Page 1: ...ngli Solar at the time of sale to the direct customer Additional recommendations are provided to enhance safety practices and performance results Please provide a copy of this manual to the PV system...

Page 2: ...PV module surfaces and do not apply paint or adhesive to any of the surfaces including the frame For your safety do not disassemble or modify Yingli Solar PV modules in any way Doing so may degrade pe...

Page 3: ...m2 AM 1 5 and 25 C cell temperature As required by the US National Electric Code NEC the short circuit current Isc should be multiplied by a factor of 1 25 and the open circuit voltage Voc should be m...

Page 4: ...rts of fixed equipment that are able to become energized by the PV system must be connected to the equipment grounding conductor in order to prevent electrical shock Refer to section 250 of the NEC fo...

Page 5: ...for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated through the...

Page 6: ...ds that PV systems be periodically inspected by the installer or other qualified person ThepurposeofthePVsysteminspectionistoensurethatallsystemcomponents are functioning properly At a minimum this in...

Page 7: ...The fifth 2014 Installation Manual_UL_ EN_201404_v02 1 August 6 2014 The sixth 2014 Installation Manual_UL_ EN_201408_v02 2 March 18 2015 The seventh 2015 Installation Manual_UL_ EN_201503_v02 3 June...

Page 8: ...t of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C Refer to module datasheets for specific power output...

Page 9: ...YL240C 30b 240 30 3 7 93 38 0 8 47 1000 15 YL235C 30b 235 29 9 7 87 37 6 8 41 1000 15 YL230C 30b 230 29 6 7 76 37 0 8 40 1000 15 YL225C 30b 225 29 4 7 66 36 4 8 39 1000 15 PANDA 48 Cell Series YL215C...

Page 10: ...0 38 07 967 43 31 1100 3 94 100 2 17 55 3 94 100 3 94 100 A A A A 38 98 990 37 24 946 1 97 50 22 72 577 16 02 408 77 56 1970 22 72 577 77 56 1970 47 24 1200 3 94 100 Grounding holes 6 0 236 6 Mounting...

Page 11: ...AR AND SIDE VIEW DIMENSIONS OF MODULE SERIES UNITS INCH mm PANDA 48 Cell SERIES PANDA 60 Cell SERIES Legend Legend Grounding holes Mounting holes Drainage holes Mounting tolerance PANDA 48 Cell PANDA...