Yingli Solar PV Modules, Installation and User Manual 

page 2

to any light. Use Insulated tools and do not wear metallic jewelry while working 
with PV modules.

In order to avoid arcing and electrical shock, do not disconnect electrical 
connections under load. Faulty connections can also result in arcing and 
electrical shock. Keep connectors dry and clean, and ensure that they are in 
proper working condition. Never insert metallic objects into the connectors, or 
modify them in any way in order to secure an electrical connection.

Do not touch or handle PV modules with broken glass, separated frames or 
a damaged backsheet unless the PV modules are first disconnected and you 
are wearing proper PPE. Avoid handling PV modules when they are wet unless 
cleaning the PV modules as directed in this manual. Never touch electrical 
connections that are wet without protecting yourself with insulated gloves.

Transport and Handling

Yingli Solar PV modules must be transported in the supplied packaging only and 
kept in the packaging until they are ready to be installed. Protect pallets against 
movement and exposure to damage during transportation. Secure pallets from 
falling over. Do not exceed the maximum height of pallets to be stacked, as 
indicated on the pallet packaging. Store pallets in a cool and dry location until 
the PV modules are ready to be unpackaged.

Figure 2: Pallet of PV modules

Yingli Solar PV modules are heavy, and should be handled with care. PV modules 
shall be handled at the frame; never use the junction box or cables as a grip. Do 
not exert mechanical stress on the cables. Never step on PV modules or drop 
or place heavy objects on them. Be careful when placing PV modules on hard 
surfaces, and secure them from falling. Broken glass can result in personal injury. 
PV modules with broken glass cannot be repaired and must not be used. Broken 
or damaged PV modules must be handled carefully and disposed of properly.

For unpacking PV modules from the Yingli Solar supplied packaging, first remove 
the pallet lid (after removing securing straps, if provided). Remove PV modules 
one at a time by sliding them up the channel in the package (see Figure 3). You 
may need to secure the remaining PV modules in the pallet packaging to prevent 
them from falling over. 

 
 

Figure 3: Removing PV modules from a pallet

Check PV modules for damage due to transportation before they are installed; 
do not install damaged modules. Contact the company you purchased the Yingli 
Solar PV modules from in order to obtain information on making claims for 
defective PV modules. 

PV module surfaces are susceptible to damage that could affect the performance 

or safety of the PV module; do not damage or scratch the PV module surfaces, 
and do not apply paint or adhesive to any of the surfaces, including the frame. 
For your safety, do not disassemble or modify Yingli Solar PV modules in any 
way. Doing so may degrade performance or cause irreparable damage and will 
void any applicable warranties. 

If it is necessary to store PV modules prior to installation, the PV modules 
should remain inside the packaging and protected from exposure that could 
compromise the durability of the packaging. 

Fire

Yingli Solar PV Modules have a Class C fire resistance rating in accordance 
with UL 1703 certification. The fire rating of this PV module is valid only when 
mounted in the manner specified in the mechanical mounting instructions. 
When PV modules are mounted on rooftops, the roof must have a fire resistant 
covering suitable for this application. PV modules are electrical generating 
devices that may affect the fire safety of a building. 

The use of improper installation methods and/or defective parts may result 
in the unexpected occurrence of an electrical arc during operation. In order to 
mitigate the risk of fire in this event, PV modules should not be installed near 
flammable liquids, gases, or locations with hazardous materials. 

In the event of a fire, PV modules may continue to produce a dangerous voltage, 
even if they have been disconnected from the inverter, have been partly or 
entirely destroyed, or the system wiring has been compromised or destroyed. In 
the event of fire, inform the fire crew about the particular hazards from the PV 
system, and stay away from all elements of the PV system during and after a fire 
until the necessary steps have been taken to make the PV system safe.

A.For cUL listed products - Class C fire rating. For UL listed products -The 
modules with the specified construction in below table, when used with a Listed 
mounting system that has been rated as a Class A System when installed with 
type 1 and/or type 2 modules, is suitable to maintain the System Class A Fire 
Rating.

Module model

Specific construction

Marking

YLxxxP-35b

Superstrate: 3.2~4.0 mm thick;
EVA: 0.43~0.5mm thick;
Substrate: 0.309 mm ~ 0.39 mm thick;
Frame: Type” Q243”, ” Q270”, ” Q293”, ” 
Q318”, ” Q320”

Module Fire 
Performance: 
Type 1

YLxxxP-35b

Superstrate: 3.2~4.0 mm thick;
EVA: 0.43~0.5mm thick;
Substrate: 0.285 mm ~ 0.295 mm thick;
Frame: Type” Q243”, ” Q270”, ” Q293”, ” 
Q318”, ” Q320”

Module Fire 
Performance: 
Type 2

YLxxxP-29b

Superstrate: 3.2~4.0 mm thick;
EVA: 0.43~0.5mm thick;
Substrate: 0.309 mm ~ 0.39 mm thick;
Frame: Type” Q282”, ” Q239”, ” Q241”, ” 
Q243”,” Q251B”, ” Q267”, ” Q268”, ” Q291”, 
” Q270”

Module Fire 
Performance: 
Type 1

YLxxxP-29b

Superstrate: 3.2~4.0 mm thick;
EVA: 0.43~0.5mm thick;
Substrate: 0.285 mm ~ 0.295 mm thick;
Frame: Type” Q282”, ” Q239”, ” Q241”, 
” Q243”, ” Q251B”, ” Q267”, ” Q268”, ” 
Q291”, ” Q270”

Module Fire 
Performance: 
Type 2

YLxxxP-23b

Superstrate: 3.2~4.0 mm thick;
EVA: 0.43~0.5mm thick;
Substrate: 0.309 mm ~ 0.39 mm thick;
Frame: Type” Q239”, ” Q241”, ” Q243”, ” 
Q267”, ” Q268”, ” Q270”

Module Fire 
Performance: 
Type 1

Summary of Contents for PANDA 48 Cell Series

Page 1: ...ngli Solar at the time of sale to the direct customer Additional recommendations are provided to enhance safety practices and performance results Please provide a copy of this manual to the PV system...

Page 2: ...PV module surfaces and do not apply paint or adhesive to any of the surfaces including the frame For your safety do not disassemble or modify Yingli Solar PV modules in any way Doing so may degrade pe...

Page 3: ...m2 AM 1 5 and 25 C cell temperature As required by the US National Electric Code NEC the short circuit current Isc should be multiplied by a factor of 1 25 and the open circuit voltage Voc should be m...

Page 4: ...rts of fixed equipment that are able to become energized by the PV system must be connected to the equipment grounding conductor in order to prevent electrical shock Refer to section 250 of the NEC fo...

Page 5: ...for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated through the...

Page 6: ...ds that PV systems be periodically inspected by the installer or other qualified person ThepurposeofthePVsysteminspectionistoensurethatallsystemcomponents are functioning properly At a minimum this in...

Page 7: ...The fifth 2014 Installation Manual_UL_ EN_201404_v02 1 August 6 2014 The sixth 2014 Installation Manual_UL_ EN_201408_v02 2 March 18 2015 The seventh 2015 Installation Manual_UL_ EN_201503_v02 3 June...

Page 8: ...t of the indicated values of Isc Voc and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C Refer to module datasheets for specific power output...

Page 9: ...YL240C 30b 240 30 3 7 93 38 0 8 47 1000 15 YL235C 30b 235 29 9 7 87 37 6 8 41 1000 15 YL230C 30b 230 29 6 7 76 37 0 8 40 1000 15 YL225C 30b 225 29 4 7 66 36 4 8 39 1000 15 PANDA 48 Cell Series YL215C...

Page 10: ...0 38 07 967 43 31 1100 3 94 100 2 17 55 3 94 100 3 94 100 A A A A 38 98 990 37 24 946 1 97 50 22 72 577 16 02 408 77 56 1970 22 72 577 77 56 1970 47 24 1200 3 94 100 Grounding holes 6 0 236 6 Mounting...

Page 11: ...AR AND SIDE VIEW DIMENSIONS OF MODULE SERIES UNITS INCH mm PANDA 48 Cell SERIES PANDA 60 Cell SERIES Legend Legend Grounding holes Mounting holes Drainage holes Mounting tolerance PANDA 48 Cell PANDA...

Reviews: