Never strike belt pulleys, coupling, pinions etc. with a hammer when pulling them onto
the shaft end. This could result in damage to bearings, the housing and the shaft.
Power transmission elements must be balanced after fitting and must not give rise to
any permissible radial or axial forces.
Observe the nameplate for maximum allowed radial and axial load. The external ra-
dial and axial load must not exceed the provided values on the nameplate.
o
Type
Hollow Shaft
Diameter
Hollow Shaft
Tolerance (H8)
Output Shaft
Diameter
Output Shaft
Tolerance (DIN748)
Up to 50mm k6
Over 50mm m6
Flange
Centering Shoulder
Diameter
Centering Shoulder
Tolerance
( g6 )
D...172/173...
30
+0.02
0
30
+0.02
0
80
-0,01
-0,03
D...272/273...
35
+0.03
0
35
+0.02
0
86
-0,02
-0,04
D...282/283...
40
+0.03
0
40
+0.02
0
110
-0,02
-0,04
D...372/373...
45
+0.03
0
40
+0.02
0
110
-0,02
-0,04
D...472/473...
50
+0.03
0
50
+0.02
0
130
-0,02
-0,04
D...572/573...
60
+0.03
0
60
+0.03
+0.01
180
-0,02
-0,05
D...672/673...
70
+0.03
0
70
+0.03
+0.01
180
-0,02
-0,05
D...772/773...
90
+0.04
0
90
+0.04
+0.02
230
-0,02
-0,05
D...872/873...
110
+0.04
0
110
+0.04
+0.02
250
-0,02
-0,05
D...972/973...
120
+0.04
0
120
+0.04
+0.02
300
-0,02
-0,05
Operating Instructions