Set DOWN limit positions:
1
.
Ensure motor has power.
2
.
Press DOWN on Manual Switch.
3
.
Please see following instructions:
When DOWN limit stop
is below required place
Press UP until blind
is at or near required
position
Rotate YELLOW knob until blind is at the
required position. Clockwise rotation will lower
the blind, anti-clockwise with raise the blind.
DOWN limit position is now set
When DOWN limit stop
is above required place
Press DOWN until
blind is at or near
required position
Rotate YELLOW knob until blind is at the
required position. Clockwise rotation will lower
the blind, anti-clockwise will raise the blind.
DOWN limit position is now set