IT IS VERY IMPORTANT

TO READ THESE

INSTRUCTIONS

THOROUGHLY

BEFORE

LIGHTING

THE STOVE

The knob for ignition and power control is located on the lower right hand side of the
stove.

If the Flame Supervision

Devise Actuating

Flame (the Pilot Light) is extinguished

either

by intention

or not, no attempt

should be made to relight until 3 minutes

have elapsed.

(i) Igniting the permanent pilot light

1

Depress control knob fully.

2

Whilst depressed,

turn knob sharply 90 degrees anticlockwise to 'PILOT'

setting

Repeat until pilot light is visibly lit, this may take several atempts.

2

With control knob at 'PILOT'

setting, turn in an anti clockwise direction to 'LOW'

setting.

Important:

Immediately

after lighting,

the stove must be left on a maximum setting for

five minutes in order to warm up the chimney.

2

Output

can be increased, by turning the control knob progressively in a clockwise

direction

until the desired level is achieved, up to a maximum as shown by the

'HIGH'

symbol on the control panel

.

1

From any heat setting, depress control knob fully and turn clockwise to 'PILOT'
position.

(v) Extinguishing the stove fully

1

From any heat setting or the permanent

pilot, depress control knob fully and turn

clockwise to 'OFF' position.

57767

Summary of Contents for DART-CPD

Page 1: ...28 MAR10m Wood multi juel and gas stoves fires and accessories DARTMOOR DART CPD GAS STOVES USER INSTRUCTIONS...

Page 2: ...checked Remember at all times this product is concerned with high temperatures and appropriate care should always be taken Bear in mind that the heat given off by the appliance may afIect articles pla...

Page 3: ...egulations and British Standards The Gas Safety Installation and Use Regulations 1994 revised 1997 The Building Regulations issued by the Department of the Environment The Building Standards Scotland...

Page 4: ...n the installer should ensure that the flue is free from obstruction and ideally a chimney should be swept and subsequently smoke tested Ensure that any dampers are fixed in a permanently open positio...

Page 5: ...il pilot light is visibly lit this may take several atempts 2 With control knob at PILOT setting turn in an anti clockwise direction to LOW setting Important Immediately after lighting the stove must...

Page 6: ...96 under new European standard EN5613 all stoves are required to have a Flame Supervision Device FSD If the pilot should become accidentally extinguished there exists a potential for a build up of unb...

Page 7: ...d be no need for the purchaser to alter the layout of the coals and it is recommended that such a practice should be avoided if at all possible Follow the instructions for coal layout in sections of t...

Page 8: ...to us postage paid for inspection via your Yeoman stockist e That our liability is limited to the free replacement part or parts affected No claims for any other work will be considered unless agreed...

Reviews: