The power cable for this fixture is 1 m

㎡,

  please mind the safety requirements 

in actual using, if any wrong operation, our company takes no responsibility for 
any loss. Also, make sure the power cord is never crimped or damaged.

 

 

 

DMX512 Channel Chart

:(

4CH

 

CH1

 

  Dimmer

 

0-255 RGBW Dimmer, from dark to bright

 

CH2

 

Red dimmer

 

0-255 Red from dark to bright

 

CH3

 

Green dimmer

 

0-255 Green from dark to bright

 

CH4

 

Blue dimmer

 

0-255 Blue from dark to bright

 

 

 

Dimmer Curves

 

 

 

Ramp Effect

 

Menu

 

Tup(ms)

 

Tdown(ms)

 

Standard Dimmer 

Curve

 

dr-0

 

0

 

0

 

Dimmer Curve

1

 

dr-1

 

980

 

1010

 

Dimmer Curve

2

 

dr-2

 

1210

 

1320

 

Dimmer Curve

3

 

dr-3

 

1600

 

1710

 

Dimmer Curve

4

 

dr-4

 

1850

 

1980

 

 

 

 

 

 

176-185

Aqua

 

Summary of Contents for YR-L0308T

Page 1: ...LED SLIM BAR Model 354SD YR L0308T YR L0309S...

Page 2: ...Board Machine Connection Section 3 troubleshooting Troubleshooting Section 4 Reference Control Menu DMX Protocol Dimmer Curve Specification Section 1 Getting Started Unpacking Safety Instruction Our c...

Page 3: ...er methods Channel 9 4CH switchable Control Mode DMX512 Manual Master Slave Sound active Cooling way no fan naturally cooling Noise silent Display LED Display DMX 3 pin XLR IP IP20 Net weight 0 75kg S...

Page 4: ...dequate ventilation at least 5m away from adjacent surfaces Be sure that no ventilation slots are blocked Some fixture may carry high heat do not aim at objective more than 2minutes Safe rope should b...

Page 5: ...DMX512 Channel Chart 4CH CH1 Dimmer 0 255 RGBW Dimmer from dark to bright CH2 Red dimmer 0 255 Red from dark to bright CH3 Green dimmer 0 255 Green from dark to bright CH4 Blue dimmer 0 255 Blue from...

Page 6: ...1 041 060 Dimmer Curve2 061 080 Dimmer Curve3 081 100 Dimmer Curve4 101 255 N A In case of failure or mis function occurred stop using immediately Never try to repair the fixture by yourself Repairs c...

Page 7: ...ling Board Machine connection Installation This machine should be mounted through the screw holes of truss Safety rope is a must to fix fixture well Make sure truss and safety rope have strong load ca...

Page 8: ...om dark to bright CH4 Blue dimmer 0 255 Blue from dark to bright CH5 Strobe 0 5 N A 6 55 Random Strobe 56 105 Pulse Strobe 106 155 Average Strobe 156 205 Thunder Strobe 206 255 Standard Strobe CH6 Col...

Page 9: ...color jump from slow to fast 10 S S000 to S255 Sound active from slow to fast 11 dr dr 0 Standard Dimmer Curve dr 1 Dimmer Curve1 dr 2 Dimmer Curve2 dr 3 Dimmer Curve3 dr 4 Dimmer Curve4 3 DMX Signal...

Page 10: ...ontroller all machines will be controlled by controller before connect to controller all machines should be in the same channel mode 9ch or 4ch Section 3 Troubleshooting Problem Probable Cause s Remed...

Page 11: ...cification Control Menu No Menu Function 1 d9 DMX 9 channel control need connecting controller 2 d 4 DMX4channel control need connecting controller 3 r r000 to r255 Red from dark to bright 4 g g000 to...