wheels balanced with the operation rod in intermediate position.
(9) Don’t place the equipment upside down when using.
(10) Please keep the equipment cleaned & out of the reach of children when not using.
(11) It is natural & normal to appear a little bit of oil leaking when transporting, loading and using it in the
first time.
4. Transport:
The equipment should be packed in carton. Please see the carrying position as below picture:.
CARRYING POSITION
CARRYING POSITION
5. Equipment Installation, Disassembly and Test.
(1) Equipment installation, when Disassemble, please see (picture A/B/C/D/E/F).
(2) Equipment Test:
a.
When the Equipment is off load within rated air pressure scope, operate the handle of hand
valve clockwise to make the Jack move up to the rated hoisting height. After reach the rated
hoisting height, boosting system stops working automatically
(The MAX. air pressure of safety
valve is 130psi). Operate the handle of hand valve anticlockwise to make the jack move down.
Dust band and sealing of cylinder work in good order without gas leaking..
b.
Test the equipment with heavy load by special testing machine. It is able to reach the rated jacking
capacity and hoisting height within the rated air pressure scope. Dustband and sealing of cylinder
work in good order without gas leaking. (The MAX. air pressure of safety valve is 130psi)
6. Operation and Maintenance.
(1) Operation of air-operated hydraulic pressure jack.
a.
Operate the handle of hand valve clockwise to carry out lifting. When the equipment lifting
to the rated height then it will stop lifting automatically by itself with the limitation system.
b.
Operate the handle of hand valve anticlockwise to carry out moving down. The equipment
will move down automatically by itself with reasonable design principle of air structure.
(2) Equipment maintenance and troubleshooting.
1) Equipment maintenance.
a. Add a few drops of lubricating oil regularly on the air inlet every 30 days once.
b. Don’t keep it at the acid, alkali and corrosive working place.
d. Check the oil tank to make sure whether there is enough hydraulic oil or not every 30 days
once.
c. Keep it clean daily after using.
Notice:
1.
Carry the equipment with hands in the (carrying
position), see picture in left side.
2.
Please operate it according to the relative warning
indication which sticks on carton.
3.
The operator can move the equipment to any
places with the help of operation rod and wheels.