5
• Sensor Type: Infrared
• Battery Type: Lithium Ion
• Charging Input Type: Micro USB
• Charging Time (starting at 0%): Approx 3 hours
• Battery Life: 8 hours
• Input Voltage: 5 V (dc) ±5%
• Input Current: 1 A ±5%
• Temperature Ranges and Humidity:
▪
Storage: -20–60°C (-4–140°F)
▪
Operating*: -20–50°C (-4–122°F)
▪
Charging: 0–45°C (32–113°F)
▪
Humidity: 95% RH NC maximum
SPECIFICATIONS
Micro USB Port
MODE
Button
Signal
LEDs
Power
LED
Sensitivity
LEDs
ON/OFF
Button
Probe Tip
• Altitude: 2000 m (6500 ft.)
• Pollution Degree: 2
• Overvoltage Category: 2
• Weight: 0.84 lb. (0.38 kg)
• Refrigerant Compatibility: Detects all CFC, HCFC, HFC and
HFO refrigerants, including blends
* Use below 0°C (32°F) should be limited
EN 14624:2020 Test Results
R-1234yf
Static lower detection limit (g/a)
1
Dynamic lower detection limit (g/a)
1
Dynamic lower detection limit in a
contaminated environment (g/a)
2
Response time (s)
0.5
Recovery time for 50 g/yr exposure** (s)
4
Calibration Frequency
Check annually with
calibrated leak standard
** As no 50 g/yr leak standard was available during testing, a 35 g/yr leak was substituted