•  Sensor Type:  Infrared
•  Battery Type:  Lithium Ion
•  Charging Input Type:  Micro USB
•  Charging Time (starting at 0%):  Approx 3 hours
•  Battery Life:  8 hours
•  Input Voltage:  5 V (dc) ±5%
•  Input Current:  1 A ±5%
•  Temperature Ranges and Humidity:

 

Storage:  -20–60°C (-4–140°F)

 

Operating*:  -20–50°C (-4–122°F)

 

Charging:  0–45°C (32–113°F)

 

Humidity:  95% RH NC maximum

SPECIFICATIONS

Micro USB Port

MODE  

Button

Signal 

LEDs

Power 

LED

Sensitivity 

LEDs

ON/OFF 

Button

Probe Tip

•  Altitude:  2000 m (6500 ft.)
•  Pollution Degree:  2
•  Overvoltage Category:  2
•  Weight:  0.84 lb. (0.38 kg)
•  Refrigerant Compatibility: Detects all CFC, HCFC, HFC and 

HFO refrigerants, including blends

* Use below 0°C (32°F) should be limited

 

EN 14624:2020 Test Results

R-1234yf

Static lower detection limit (g/a)

1

Dynamic lower detection limit (g/a)

1

Dynamic lower detection limit in a 
contaminated environment (g/a)

2

Response time (s)

0.5

Recovery time for 50 g/yr exposure** (s)

4

Calibration Frequency

Check annually with 

calibrated leak standard

** As no 50 g/yr leak standard was available during testing, a 35 g/yr leak was substituted