If the refrigerant tested is 98% pure or better, and the air content
is less than 10%, the “PASS” screen will display and the Green LED
will illuminate. Should the refrigerant be less than 98% pure or
the air content greater than 10%, the “FAIL” screen will display and
the Red LED will illuminate. In either case, selecting the “MORE”
button will display the details in
Figure 11
for “PASS” and
Figure
12
for “FAIL”.
RESULTS………PASS
R134 100.0%
R12
.0%
R22
.0%
HC
.0%
AIR
2.8%
EXIT
RESULTS………….FAIL
R134
95.0%
R12
5.0%
R22
.0%
HC
.0%
EXIT
2.5
Blend Refrigerants
The refrigerant identifier includes the “Blend ID” feature for
determining the presence of EPA S.N.A.P approved blend refrigerants.
In the event that the refrigerant identifier determines that the
refrigerant in the system or cylinder is possibly a S.N.A.P. blend,
the results will display as follows in
Figures 13
,
14
, and
15
. Note
that pressing the additional “MORE” button on the screen in
Figure
14
will take the user to the Blend Refrigerant screen shown in
Figure 15
. Note: This screen will vary based on the test results.
FAIL
R12
92.7%
HELP MORE
RESULTS………….FAIL
R12
7.3%
R134
92.7%
R22
.0%
HC
.0%
EXIT MORE PRINT
POSSIBLY ONE OF
THE FOLLOWING
BLEND
REFRIGERANTS
FREEZE 12
FREE ZONE OR
RB-276
DONE
Pressing the “DONE” button in
Figure 15
will return the user to the
screen shown in
Figure 14
.
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
15