background image

INTRODUCTION

The Yellow Jacket

TM

 52030F Thermal Imager is an accurate, high-quality 

handheld thermal imaging camera.  The 52030F has been designed 
exclusively for the purpose of performing elevated skin temperature 
screening.  The 52030F thermal imager meets the recommendations 
established by the U.S Food & Drug Administration (FDA) for elevated skin 
temperature screening.  The 52030F has a measurement accuracy of ±0.9F 
(±0.5C) over a temperature screening range of 93.2-102.2°F (34-39°C).  
The thermal imaging camera has been calibrated in the factory using 
a blackbody temperature reference source.   No on-site calibration is 
required. 

Meets international performance standards for thermographic devices. 
Not FDA-cleared or approved.

KEY FEATURES

• Designed exclusively for elevated skin temperature screening
• 80x60 thermal resolution or 4800 temperature measurement points
• 9Hz frame rate.  The camera creates images at the rate of 9 per second
• Hot, Cold, Center temperature tracking
• Large, easy-to-read graphical TFT display
• Buzzer alarm
• 6 hours operating time with rechargeable battery
• Compact, rugged design

PRODUCT USE RECOMMENDATIONS

• Please read this Operating Manual carefully before using the 
   thermal imager
• The optimal measuring distance for this product is 3 feet.
• To ensure measurement accuracy, please use the product in an 
  operating environment of 59°F to 86°F (15°C to 30°C), <85% relative 
  humidity (non-condensing).
• Please use the thermal imager indoors and in a room with minimal air 
  movement.  When changing to a new environment, please turn on the 

  thermal imager 10 to 15 minutes before you begin taking measurements.
• The ambient temperature for measuring must be stable.  Do not measure 
  in places where there is a lot of airflow from fans or air outlets.
• If the person being measured has been in a place where the temperature 
  was significantly warmer or cooler than the measurement environment, 
  have that person remain in the measurement room for 10 to 30 minutes 
  before taking their temperature.
• The 52030F measures the surface temperature of an object. If 
  temperature compensation is needed, please adjust in the Settings menu.
• The thermal imager is self-calibrating. If the reading jumps quickly, allow 
  the measurement to steady before taking a reading.
• After measuring extremely high or low temperature objects, leave the 
  product alone for about 10 minutes before next use.
• Do not use the product in places with strong sunlight or electromagnetic 
 interference.
• Please do not use this product in flammable, explosive, steamy, wet or 
  corrosive environments.
• Please stop using the product if it has been damaged or modified to avoid 
  inaccurate measurement results.
• Highly Recommended:  For high measurement accuracy, ensure that the 
  emissivity setting in the thermal imager matches the surface material (ex. 
  human skin) you are measuring.  
• For better results, , please warm-up the thermal imager for 10 minutes 
  before performing measurements.
• When the battery is being charged, the internal temperature of the 
  product will increase.  This can impact the accuracy of temperature 
  measurements.   Therefore, it is not recommended to take measurements 
  while the product is being charged or right after it has been charged.  

 

IMPORTANT INFORMATION CONCERNING 

ELEVATED SKIN TEMPERATURE SCREENING

• 

Temperature measurement should not be solely or primarily relied upon  

  to diagnose or exclude a diagnosis of COVID-19, or any other disease 

Summary of Contents for 52030F

Page 1: ...ellow JacketTM 52030F Thermal Imager Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2020 Southwire Co...

Page 2: ...easurements The ambient temperature for measuring must be stable Do not measure in places where there is a lot of airflow from fans or air outlets If the person being measured has been in a place wher...

Page 3: ...ng camera in a room with minimal movement of air out of direct sunlight and away from radiant heat for example portable heaters electrical sources Avoid strong lighting for example incandescent haloge...

Page 4: ...Tripod mounting hole 11 Flashlight button 12 Left button 13 Down button 14 Right button 15 Back button 16 Replay button 17 Up button 18 SET button THE THERMAL IMAGER DISPLAY 1 Temperature unit option...

Page 5: ...y 2 Use the up down left right buttons to select the desired image 3 Press the SET button to view the image in full screen mode 4 Press the SET button in full screen mode to delete the image or view i...

Page 6: ...select the cursor symbol 3 Press the SET button to enter the cursor submenu 4 Press the up down button to select the temperature unit symbol 5 Press the SET button to confirm 6 The high temperature in...

Page 7: ...t button to select the parameter to be adjusted 4 Press the SET button 5 Press the up down button to increase or decrease the value 6 Press the SET button to save the settings and return to set other...

Page 8: ...SET button to confirm 5 Press the back button to exit the current menu Emissivity submenu 3 Press the up down button to select emissivity or temperature compensation 4 Press the SET button to enter t...

Page 9: ...rature 7 Press the back button to exit the current menu DEVICE INFORMATION TO VIEW INFORMATION ABOUT THE THERMAL IMAGER 1 Press the up down button to select the Device Info option in the settings menu...

Page 10: ...n the thermal imager back to the original factory values do the following 1 Press the up down button to select the Factory Reset option in the settings menu 2 Press the SET button to enter the Factory...

Page 11: ...Normal Mode 0 9 F 0 5C at 25 C ambient temperature MEASUREMENT ANALYSIS Emissivity Correction Variable from 0 01 to 1 0 STORAGE OF IMAGES Image Storage format BMP Micro SD card DATA COMMUNICATION INTE...

Page 12: ...outer shell lens or window COMPLIANCE CE Lithium battery is compliant with UN 38 3 UL 1642 and UL 2054 Product is compliant with FCC 47 CFR Part 15B PACKAGE CONTENTS 1 Yellow Jacket 52030F thermal im...

Page 13: ...C a 30 C con menos del 85 de humedad relativa sin condensaci n Use el term grafo en interiores y en una sala con la menor circulaci n de aire posible Cuando cambie de entorno encienda el term grafo de...

Page 14: ...N DE TEMPERATURA ELEVADA EN LA PIEL De acuerdo con las directrices ISO TR 13154 2017 sobre el uso de term grafos Se recomienda una temperatura ambiente de 64 a 86 F de 18 a 30 C c on una humedad relat...

Page 15: ...alrededor de 21 en vertical por 21 en horizontal El rea de la imagen debe abarcar toda la cara de la persona Si se observa un aumento de la temperatura por medio del sistema de diagn stico por im gen...

Page 16: ...INTRODUCCI N AL MEN INSTRUCCIONES DE USO CAPTURA DE IM GENES 1 Tire del disparador y su ltelo para cap turar una imagen t rmica Consulte la secci n que se encuentra casi al final de este manual llamad...

Page 17: ...para PC 3 Los usuarios pueden explorar las im genes y analizar los datos con el software para PC Nota No desconecte el cable USB mientras el software est cargando im genes INFORMACI N DE LA TARJETA SD...

Page 18: ...tura 5 Presione el bot n de ajustes para confirmar 6 El indicador de temperatura alta se enciende y aparece la temperatura correspondiente en la esquina superior izquierda 7 Presione el bot n para vol...

Page 19: ...zamiento hacia la izquierda o derecha para seleccionar el par metro que desea ajustar 4 Presione el bot n de ajustes 5 Presione el bot n de desplazamiento hacia arriba o abajo para aumentar o disminui...

Page 20: ...030F se apagar de forma autom tica una vez transcurrido el tiempo preestablecido Para configurar el per odo de apagado autom tico siga estos pasos 1 Presione el bot n de desplazamiento hacia arriba o...

Page 21: ...1 Presione el bot n de desplazamiento hacia arriba o abajo para seleccionar la opci n HI LO Alert Alerta alta baja en el men de ajustes 2 Presione el bot n de ajustes para ingresar al submen HI LO Al...

Page 22: ...ar la opci n Format SD Formatear SD en el men de ajustes 2 Presione el bot n de ajustes para ingresar al submen Format SD Formatear SD 3 Presione el bot n de desplazamiento hacia arriba o abajo para s...

Page 23: ...de 0 01 a 1 0 ALMACENAMIENTO DE IM GENES Formato de almacenamiento de im genes BMP tarjeta Micro SD INTERFACES DE COMUNICACI N DE DATOS Bluetooth N A SISTEMA DE ALIMENTACI N Bater a Bater a de iones d...

Page 24: ...as normas UN 38 3 UL 1642 y UL 2054 El producto cumple con la parte 15B de la norma FCC 47 CFR CONTENIDO DEL PAQUETE 1 C mara de im genes t rmicas Yellow Jacket 52030F 2 Cable USB de transferencia de...