Connections
The SDI Video in- and outputs are connected to the corresponding 75
Ohm BNC connections provided. The fiber connection is made to the LC
connector as indicated on the module. An example of a LC connector
shown below.
OTR 1810-1 LC (Singlemode) and MM (Multimode) both use a dual LC
connection. Please use the appropriate cable type for the module.
Use the included dust plug to protect the optical connection from dust.
Operation
The OTR 1810-1 supports any SDI video signal from 270Mbit/s to
3Gbit/s. The fiber input wavelength for the singlemode module is
1270nm - 1610nm and for multimode 760nm - 870nm. Data reception
activity is indicated by the RX LEDs on the side of the module.
Operation is fully automatic. The fiber input video rates are
automatically detected, reclocked and provided on the BNC output
connectors. No user settings are provided for this module. The module
supports hot swapping and hot plugging of connections.
Note:
If TX LED is OFF this indicates no SDI input is present, or the input signal is
not valid. If RX LED is OFF this indicates no signal is present, signal to weak or is a
non a valid input.
Power
The module requires a clean 12V DC (7-24V DC) power source. An LED is
provided to confirm power is connected. A 12V DC power supply is
included with the module. If you are applying your own power source,
please provide a clean, 7-24V DC power source. Power consumption
information can be found in the technical specifications table.
Note:
The module is designed for use with
either single- or multimode fiber cable.
Note:
OTR 1810-1 is identical in terms of mounting and securing
Optional Mounting Brackets
The optional RFR 1001 mounting brackets can be
used to permanently mount the modules on any
flat surface or on 19‘‘ rack rails.
Power Lead Strain Relief
The modules have a small hole in the case located above the power
connection to prevent the power lead being accidentally pulled out.
Use the supplied tie-wrap and secure the lead as shown below.
The optional RFR 1000-1 rack mount can be used to permanently
mount up to 14 yellobrik modules. In addition, the RFR 1000-1 can
provide full power redundancy for all mounted yellobriks.