![background image](http://html1.mh-extra.com/html/yeastar-technology/ta-series/ta-series_how-to-connect_3300382013.webp)
How to Connect Yeastar TA FXS Gateway to 3CX
Figure 20. Create DID on 3CX Phone System
Inbound route name:
From_NeoGateTA3200
DID/DDI number/mask:
9999, which is the same with the trunk external number.
Available ports:
NeoGate_TA3200
Office Hours:
Connect to Digital Receptionist
Now you can make calls from the phone which is connected to TA3200 FXS port1 to
3CX phone system by dialing number 9999. The call will reach the IVR 800.
Step 6. Create an outbound rule on 3CX phone system.
Click "Create Outbound" on 3CX phone system.
Figure 21. Add Outbound Route
Rule Name:
To_NeoGate_TA3200
Prefix:
9
Call from extension(s):
100-105
Route:
NeoGate_TA3200
13/14