background image

 

 

EtherAnt II User’s Manual 

2.4 Power 

Supply 

The EtherAnt II antenna kit comes with a 110 VAC to 15 VDC power supply that has a standard barrel 
plug [center pin positive (+) tip and outer ring negative (-)].  110/220 VAC “laptop-type” power supplies are 
available as an option.  The EtherAnt II –LR version comes standard with the 110/220 VAC “laptop-type” 
adapter.  Although normally provided with a power supply, any power source meeting the following 
specifications can be used: 

 

EtherAnt II 

12-24VDC @ 500 mA 

maximum cable length: 300 feet 

EtherAnt II-LR 

15VDC @ 1300 mA 

maximum cable length: 100 feet 

 

CAUTION: 

Operating the EtherAnt II-LR version with more than 15 VDC will damage it. Operating it with 
less than 15 VDC will cause improper operation. 

2.5 

Aiming Antenna and Checking Signal Strength 

The EtherAnt II has a built-in signal strength indicator which can be monitored by the YDI Client Manager 
software to help optimize the aiming of the antenna.  If you are using an ORiNOCO or YDI Access Point 
in your wireless network, you can also use the Link Test capability of the AP Manager software to monitor 
the signal strength of the EtherAnt II into the base unit. 
 
Another test that can be performed involves using a laptop computer, a YDI Sapphire or Diamond WLAN 
card, and the Wireless Client Manager program that comes with it.  Insert the WLAN card in the laptop 
computer, install the program and run it.  The 

Advanced -> Link Test

 screen of the Wireless Client 

Manager program shows signal strength levels.  Walk around the desired coverage areas with the laptop 
computer and record the signal levels.  This way you can build a map of the areas that have good 
coverage. 
 
For details about how to set up, configure, and use the Wireless Client Manager program, please refer to 
the User Manual of the product. 

2.6 Hardware 

Installation 

Perform the following procedures once you have determined the optimal location for the antenna: 
 

1.  If you are going to install the antenna on a mast or pipe, use the brackets and screws to mount 

the flat panel antenna to a pole with a maximum diameter of up to 1 3/4 inches. 

 
2.  Ensuring that there is no DC power applied to the DC Power Injector, plug the 6-pin N-male round 

connector of the outdoor Ethernet cable provided into the rear jack of the flat panel antenna, 
aligning the notch on the connector with the tab on the jack as shown on Figure 2.3. Then turn 
the round locking nut clockwise as you push in until it securely fastens onto the jack. 

Please 

verify that the round connector is properly plugged into the rear jack of the antenna prior 
to connecting DC power

 because it is possible to push it in the wrong way if enough force is 

used. If DC power is applied and the connector is not properly plugged, damage to the electronics 
of the unit or the connector itself may occur which will not be covered by the factory warranty. 

 
3.  Attach the other end of the outdoor Ethernet cable provided to the Cat 5 DC Power Injector at 

port RJ-45 labeled “To ANT.” 

 

Version 3.3 

Page 6 

March 2003 

Summary of Contents for EtherAnt II-LR

Page 1: ...Version 3 3 March 2003...

Page 2: ...any of the following occurs 1 The product enclosure is opened 2 The antenna connections are not properly waterproofed 3 The device is installed improperly or with incorrect connectors 4 The round conn...

Page 3: ...ation 6 Section 3 The Client Manager 8 3 1 Installation 8 3 2 Using the Client Manager 9 3 3 General Information 10 3 4 Configuration 15 3 5 Utilities 18 3 6 Removing the Program 21 Appendix A Frequen...

Page 4: ...utomatically routes IP packets for up to 253 MAC addresses on the LAN no special configuration is necessary The Micro routing algorithm maintains an auto indexed IP to MAC address table by inspecting...

Page 5: ...gain and 15 beamwidth Transmit power of 2 Watts EIRP and 16 Watts EIRP on LR model Up to 4 5 Mbps actual throughput FCC Part 15 Certified for license free operation 11 channels in USA Professional ins...

Page 6: ...ast tilt bracket mount Outdoor Ethernet cable with weatherproof antenna connector 50 feet standard can be optionally extended up to 300 feet for standard series and up to 100 feet for LR models Cat 5...

Page 7: ...prior to deploying it in the field Set up a mini network that resembles your actual configuration as close as possible By using such a mock up troubleshooting potential problems will be much easier t...

Page 8: ...tenna is aimed at a vertically polarized omni directional or sector base station antenna it must be mounted vertically polarized using the other mounting stud on the back Figure 2 1 Outdoor Pole Mount...

Page 9: ...ed Link Test screen of the Wireless Client Manager program shows signal strength levels Walk around the desired coverage areas with the laptop computer and record the signal levels This way you can bu...

Page 10: ...er Injector 6 Check that the Power and Ethernet LEDs are lit For LR models check that the RX Power amplifier LED green is also lit 7 Configure the EtherAnt II Client Adapter using the Client Manager s...

Page 11: ...the contents of the CD ROM drive and select the following directory Management YDI Client Manager Run the Set Up program 2 The Splash screen will appear first Choose Next to continue the installation...

Page 12: ...ther user will be given access to that EC Once the logged in user logs out the status will then reflect whether it is online or offline Figure 3 1 Select EC Screen A number of other functions can be p...

Page 13: ...ressing this button will restore the parameters that are currently saved in the attached EC General Information This screen automatically displays information about the connection with the device you...

Page 14: ...splays the IP address of the computer you are using Ethernet Converter Name This read only property displays the name of the EC you are currently connected to Ethernet Converter IP This read only prop...

Page 15: ...C Address of the most recently received Ethernet frame from the Ethernet port will be used Note this setting disables Micro routing If Use EC MAC Address is clicked the internal MAC Address of the uni...

Page 16: ...Antenna Selection This option only available for the Design In model allows the user to select which antenna port on the 802 11 b PCMCIA Card to use Figure 3 5 Options Ethernet Figure 3 6 Options PC C...

Page 17: ...designed to help you configure one or two ECs from the default configuration to the configuration that matches your needs This includes the wireless and Ethernet settings Serial Configuration Wizard A...

Page 18: ...n Gateway This field sets the IP Address of the Gateway router or firewall You will need to enter the IP address of your gateway particularly if you plan to use the EC to access computers or other Eth...

Page 19: ...t Peer to Peer if you are setting up an Ad Hoc group or Wireless Link if you are setting up a wireless bridged network Note Wireless Link mode disables Micro routing Figure 3 11 Wireless Configuration...

Page 20: ...key see Figure 3 13 Use Key This field allows you to choose which key to use for encryption Encryption Type This field allows you to specify whether to use a 64 bit or a 128 bit encryption key For a 1...

Page 21: ...ent Manager installed because the settings are stored in the non volatile memory of the EtherAnt II 3 5 Utilities Diagnostic Utility Figure 3 14 The Diagnostic Utility Screen is invaluable for checkin...

Page 22: ...ckets are received the diagnostic utility screen will update the number of successfully received packets at each specified rate These signal levels are also very useful for aiming the antenna Adjust t...

Page 23: ...ocess fails the CM displays a warning message clearly stating that the update has failed The user should then attempt to log back in via the CM and re run the update process After the process is done...

Page 24: ...u through this process The latest firmware can be found at www ydi com support downloads php Firmware and Client Manager software are distributed together to ensure synchronized capability and feature...

Page 25: ...only be fixed at our facilities 3 Why can I not log on Client Manager Only one Client Manager Login is allowed at a time The Client Manager will not allow two users to log on simultaneously 4 Why does...

Page 26: ...r needs to be set to the default value of Large meaning there are not many APs covering the area This keeps client devices from easily wandering off looking for other APs if there is any kind of trans...

Page 27: ...EtherAnt II User s Manual Version 3 3 Page 24 March 2003...