Operation
- Before entering TIMER setting, make sure power is being supplied to the unit.
- Before entering TIMER setting, make sure pressing Setting Button sets one
desired room humidity first.
-5-
SPEED Button
Control the fan speed. Press to select either High or Normal fan speed. A higher
fan speed will result in quicker moisture removal. Set the fan control to High for
maximum moisture removal. When the humidity has been reduced and quiet
operation is preferred, set the fan control to Normal.
"
BUCKET FULL" Indicator Lights
When the bucket is full, the light will flash and the machine will automatically shut
off. After the water in the bucket is emptied, put the bucket back in place, then the
indicator will go out, and the machine will restart.
Auto Defrost Feature
When the dehumidifier is running at a lower temperature, the system
will automatically determine if there is frost, and if if frost is present,
it will automatically defrost.
Defrost action
The fan runs at high wind speed while the compressor stops, and the
LED screen display the defrosting symbol.
Power on:
Compressor start after fan work a few seconds.
Power off:
Compressor shut down at once, after a few seconds, the
fan stop (when other malfunctions occurs or humidity reached the
desired level, the fan will stop after tens of seconds ).
Tips: The compressor features "3 minutes delay protection"
unction —— While the dehumidifier is powered, the compressor
can only start again three minutes after its last shutdown.
Action Description
Note:
Summary of Contents for PD161D
Page 1: ...PD161D...