A
B
C
D
A
A
A – Sealing nut
B – Clamping claw
C – Sealing insert
D – Cable gland body
Figure 7.29 Cooling Fan Cable Gland: 4A0124
7.
Pull the clamp claw and sealing nut insert from the gland body and separate the pieces.
C
A
B
A – Clamping claw
B – Sealing insert
C – Opening
Figure 7.30 Separate the Clamping Claw and Sealing Insert: 4A0124
8.
Pull apart the opening on the sealing insert then remove it from the wiring. Slide the sealing nut and clamping claw
off the power lines.
7.5 Drive Cooling Fans
288
YASKAWA ELECTRIC SIEP YAIZ1B 01E YASKAWA AC Drive – Z1000 Bypass Technical Manual