XtraDrive-DP Parameters List
A
PPENDIX
B
Last printed: 6/1/03 4:24 PM
AppBParameters.doc
Last saved: 6/1/03 8:57 AM
49
B
X
traD
rive-
D
P Parameters List
BB
X
traD
rive-
D
P Parameters List
Module Name
Description
Pn103: Inertia Ratio
Inertia Ratio:
This parameter enables
you to enter a rough estimation of your
system’s external load, as a percentage
of the motor’s inertia.
Pn110.0
Reserved
Pn110.1
Reserved
Pn110.2
Reserved
Pn110.3
Reserved
Pn200.0: Reference Pulse
Form
Reference Pulse Form:
0 — Sign & pulse, positive logic
1 — CW & CCW, positive logic
2 — AB (x1), positive logic
3 — AB (x2), positive logic
4 — AB (x4), positive logic
5 — Sign & pulse, negative logic
6 — CW & CCW, negative logic
7 — AB (x1), negative logic
8 — AB (x2), negative logic
9 — AB (x4), negative logic
Sy
ste
m Pa
ra
me
te
rs
Pn200.1: Error Counter
Clear Signal Form
Error Counter Clear Signal Form:
0 — Clear error counter when
signal=high
1 — Clear error counter on signal rising
edge
2 — Clear error counter when
signal=low
3 — Clear error counter on signal falling
edge
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20
Web : http: www.audin.fr - Email : [email protected]