background image

YASKAWA ELECTRIC

 TM.V1000SW.134A 1000 Hz High Frequency Custom Software Supplement

3

Table of Contents

1 PREFACE AND SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 MODIFICATIONS FROM STANDARD SOFTWARE  . . . . . . . 9
4 MODIFIED PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5 NEW AND MODIFIED SOFTWARE FUNCTIONS  . . . . . . . . 14
6 APPLICATION NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Refer to the V1000 Technical Manual for content not described in this document.

Summary of Contents for VU*B****AA*-134 Series

Page 1: ...e V1000 Option 1000 Hz High Frequency Custom Software Supplement Software No VSV91005X To properly use the product read this manual thoroughly and retain for easy reference inspection and maintenance...

Page 2: ...r written permission of Yaskawa No patent liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is constantly striving to improve its high quality p...

Page 3: ...ment 3 Table of Contents 1 PREFACE AND SAFETY 5 2 PRODUCT OVERVIEW 8 3 MODIFICATIONS FROM STANDARD SOFTWARE 9 4 MODIFIED PARAMETERS 10 5 NEW AND MODIFIED SOFTWARE FUNCTIONS 14 6 APPLICATION NOTES 16 R...

Page 4: ...4 YASKAWA ELECTRIC TM V1000SW 134A 1000 Hz High Frequency Custom Software Supplement This Page Intentionally Blank...

Page 5: ...sive or sole safety control Without exception all controls should be designed to detect faults dynamically and fail safely under all circumstances All systems or equipment designed to incorporate a pr...

Page 6: ...he effect of this custom software on the parameters in the drive and function descriptions in the manual To obtain the supplement access this site U S http www yaskawa com Yaskawa AC Drive V1000 1167...

Page 7: ...nt is a supplement to the standard drive technical manual It describes the effects on the drive parameters and functions with the software installed Custom software is provided to add functionality to...

Page 8: ...The drive s maximum output frequency can be set up to 1000 Hz Non applicable drive functions are deleted in order to optimize CPU processing time for this software Applicable Models The 1000 Hz Optio...

Page 9: ...isplay units 2 3 o1 03 parameter same as b5 20 0 0 1 Hz 1 0 01 Max frequency 100 2 Deleted 3 User Defined o1 10 and o1 11 o1 03 parameter same as b5 20 0 0 1 Hz 1 0 01 Max frequency 100 2 RPM 3 User D...

Page 10: ...Estimation Type b3 10 Speed Search Detection Compensation Gain Estimation Type b3 24 Speed Search Method Selection b8 01 b8 19 Energy Saving Control Parameters C6 01 Normal Heavy Duty Selection E3 01...

Page 11: ...0 0 3000 0 s b5 20 PID Setpoint Scaling 0 1 3 H6 01 Pulse Train Input Terminal RP Function Selection 0 1 2 L3 02 Stall Prevention Level during Acceleration 0 170 L3 04 Stall Prevention Selection duri...

Page 12: ...quency Reference 12 0 0 1000 0 0 0 Hz d1 13 Frequency Reference 13 0 0 1000 0 0 0 Hz d1 14 Frequency Reference 14 0 0 1000 0 0 0 Hz d1 15 Frequency Reference 15 0 0 1000 0 0 0 Hz d1 16 Frequency Refer...

Page 13: ...ncy Reference 0 0 1000 0 Hz U1 02 Output Frequency 0 0 1000 0 Hz U1 16 Output Frequency after Soft Start 0 0 1000 0 Hz U2 03 Frequency Reference at Previous Fault 0 0 1000 0 Hz U2 04 Output Frequency...

Page 14: ...tion Notes on page 16 for more information Table 12 Carrier Frequency Selection Parameter C6 02 Settings Figure 1 Figure 1 Additional Carrier Frequency Patterns C6 02 Carrier Frequency Selection C6 03...

Page 15: ...boost above 120 Hz and eliminate voltage boost above 160 Hz as shown in Figure 2 Figure 2 Figure 2 Torque Compensation Gain On Delay Compensation High speed motors typically operate at low V f ratios...

Page 16: ...meter Generally the peak of the motor current waveform should not exceed 100 continuous drive HD nameplate x 2 5 This value may vary slightly by drive model Refer to Figure 4 for an example of peak c...

Page 17: ...ble 2 To create a ramped carrier frequency pattern to keep the output frequency and carrier frequency at a constant ratio Set C6 02 F to build a custom pattern Set C6 03 7 0 kHz so the motor will run...

Page 18: ...put reactor it may be advantageous to oversize the drive to accommodate the high peak current that may result from the low impedance motor Using a drive that is at least one or two models larger than...

Page 19: ...ICA In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture thereof the export will fall under the relevant re...