VAN-V07007E
[J7
→
J1000] Replacement Instructions
12/16
J7
J1000
Drive
Function/
Parameter
Parameter
No.
Initial Value
Parameter
No.
Initial Value
Comments
Terminal MA,MB,MC
function selection
n40 1 H2-01 E
J7 J1000
n40
→
0 H2-01
→
E
n40
→
1 H2-01
→
0
n40
→
2 H2-01
→
2
n40
→
3 H2-01
→
1
n40
→
4 H2-01
→
5
n40
→
5 H2-01
→
4
n40
→
6 H2-01
→
B
n40
→
7 H2-01
→
17
n40
→
10 H2-01
→
10
n40
→
11 H2-01
→
8
n40
→
12 H2-01
→
3C
n40
→
13 H2-01
→
6
n40
→
14 H2-01
→
1E
n40
→
15 H2-01
→
7
n40
→
16 H2-01
→
1A
n40
→
17 H2-01
→
3D
n40
→
18
F (through mode)
Analog input FR gain
n41 100% H3-03 100.0
%
Analog input FR bias
n42 0% H3-04 0.0
%
Analog input filter time
constant
n43
0.10 s
H3-13
0.03 s
Analog output AM
function selection
n44 0 H4-01 102
J7 J1000
n44
→
0 H4-01
→
102
n44
→
1 H4-01
→
103
Analog output AM gain
n45 1.00 H4-02
100.0%
Set H4-02 = n45 * 100
Carrier frequency
selection
C6-02
o2-04
dep.
Carrier frequency
upper limit
C6-03 C6-02
dep.
Carrier frequency
lower limit
C6-04 C6-02
dep.
Carrier frequency
proportional gain
n46
4
(depending
on drive
size)
C6-05 0
J7 J1000
n46
→
1 C6-02
→
1 (2kHz)
n46
→
2 C6-02
→
2 (5kHz)
n46
→
3 C6-02
→
3 (8kHz)
n46
→
4 C6-02
→
4 (10kHz)
n46
→
7
C6-03 = 2.5
C6-04 = 1.0
C6-05 = 12
n46
→
8
C6-03 = 2.5
C6-04 = 1.0
C6-05 = 24
n46
→
9
C6-03 = 2.5
C6-04 = 1.0
C6-05 = 36
Momentary power loss
detection selection
n47 0 L2-01 0
J7 J1000
n47
→
0 L2-01
→
0
n47
→
1 L2-01
→
1
n47
→
2 L2-01
→
2
Automatic fault reset
attempts
n48 0 L5-01 0
Jump frequency 1
n49 0.0Hz d3-01 0.0Hz
Jump frequency 2
n50 0.0Hz d3-02 0.0Hz
Jump frequency
bandwidth
n51
0.0 Hz
d3-04
1.0 Hz