15.3.4 Intermittent Load Operating Capacity
1
5
-18
15.3.4 Intermittent Load Operating Capacity
If operations, such as tapping a machine-tool or driving a conveyer table, are frequently reversed, care must
be taken in selecting the capacity. When using an operation cycle that includes acceleration/deceleration
operations such as those shown in Fig. 15.19, make a selection so that the motor equivalence efficiency
torque
T
R
is less than the inverter continuous rated torque. (The maximum value of
T
P
will be 120% of
the Inverter 30 min. rating.)
T
R
=
(N
•
m)
T
P
2
(
t
r
+
t
f
) +
T
L
2
t
s
t
C
Motor torque
Motor speed
t
r
t
c
t
s
T
L
T
P
−
T
P
N
M
Time
Time
t
f
Fig 1
5
.
19
Motor Torque and Speed Timechart
The motor reverse rating is the rating over the load where the motor load changes cyclically. When the
reverse rated output is taken to be
t
1
, and with no load is taken to be
t
2
, a as expressed in the following
formula is called %ED (Einschalt Dauer).
t
1
+
t
2
is regulated to 10 minutes.
α
=
t
1
t
1
+
t
2
×
100
(%)
15