14.1 Drives
1
4
-3
Model CIMR-M5
j
*
1
23P7
23P5
27P5
2011
2015
2018
2022
2030
2037
Continuous Rated Input Cur-
rent (A)
17.6
17.6
26.2
35.7
52.4
71.4
88.1
104.8
142.8
Continuous Rated Output Cur-
rent (A)
21
21
31
40
56
80
98
113
160
Control Method
Sine wave PWM Inverter (Vector control)
rter
Speed Control Range
40 min
−
1
to maximum motor speed
nver
t
Speed Regulation
0.2% maximum speed or less
In
Overload Capacity
120%, 60s of 30-minute rating
Approx. Mass
lb (kg)
11 (5)
27 (12)
35 (16)
57 (26)
Dimensions in
inches
Width
3.94 (100)
5.91 (150)
7.84
(200)
11.81
(300)
inches
(mm)
*2
Height
13.78 (350)
(mm)
2
Depth
12.60 (320)
Model CIMR-MR5
j
*
1
23P7
25P5
27P5
2011
2015
2018
2022
2030
2037
Required Power Capacity
(kVA)
7
9
12
19
24
30
36
48
60
Continuous Rated Input Cur-
rent (A)
13.3
13.3
19.7
26.8
39.3
53.6
66.1
78.6
107.2
Continuous Rated Output Cur-
rent (A)
17.6
17.6
26.2
35.7
52.4
71.4
88.1
104.8
142.8
Power Supply
Three-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to
−
15%, allowable frequency fluctuation:
±
5%,
Line-to-line voltage unbalance: 5% or less)
Controller
onverter
*
3
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to
−
15%, allowable frequency fluctuation:
±
5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
C
Co
Control Method
Power regenerative control (120
_
current conduction)
Overload Capacity
120% for one minute, 200% for one second
Approx. Mass
lb (kg)
11 (5)
27 (12)
35 (16)
57 (26)
Dimensions in
inches
Width
3.94 (100)
5.91 (150)
7.84
(200)
11.81
(300)
inches
(mm)
*2
Height
13.78 (350)
(mm)
2
Depth
12.60 (320)
Power Supply AC Reactor
Code No.
X010057 X010058
X010059
X010060
X010061
X010062
X010063
X010064
X010120
Model CIMR-M5
j
*
1
CIMR-MR5
j
*
1
23P7
25P5
27P5
2011
2015
2018
2022
2030
2037
Ambient Temperature
0
°
C to 55
°
C (32
°
F to 131
°
F) (not frozen)
n
Heatsink Intake Air Tempera-
ture
0
°
C to 45
°
C (32
°
F to 113
°
F)
m
mon
Storage Temperature
*4
−
20
°
C to 60
°
C (
−
4
°
F to 140
°
F)
C
om
m
Humidity
90% or less (non-condensing)
C
Location
Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less
Vibration
9.8 m/s
2
(1G) at 10 to less than 20 Hz, up to 2 m / s
2
(0.2G) at 20 to 50 Hz
Protective Structure
IEC IP00
(Protected so that parts of the human body cannot reach electrically charged parts from the front)
* 1. A: For stand-alone drive system N: for NC system
* 2. Dimensions of External Heatsink Cooling Type. Refer to
14.1.3 Dimensions
for Open Chassis Type.
* 3. An AC reactor is required between Converter and main circuit power supply.
* 4. Temperature during shipping.
14
Summary of Contents for VS-626M5