YASKAWA VARISPEED-656RC5 Manual Download Page 9

10

PERIPHERAL DEVICES

Connect the specified AC reactor and AC main circuit fuses when operating the  VS-656RC5.

Input AC Reactor

(Type UZBA-B, for 50/60 Hz)

Power Coordinating Reactor

An input three-phase reactor

corresponding to each model is

necessary when operating VS-

656RC5. This input AC reactor is

effective against saturated current

and excessive heat.

Check the table below and use a

specified AC reactor.

〔Connection Example〕 

MCCB Power Coordinating Reactor

Current Suppressing Reactor

Inverter

Motor

IM

R
S

T

R

VS− 
656RC5

S
T

FU

U

V

W

VS−656RC5 
CIMR−R5A 

=

Current 

Value A

Inductance 

mH

Code No.

Fig.

Dimensions mm

Approx. Mass 

kg

Loss 

W

A

B

B1

C

D

E

F

H

J

K

L

M

23P7 
25P5 
27P5 
2011 
2015 
2018 
2022 
2030 
2037

20 
30 
40 
60 
80 
90 

120 
160 
200

0.53 
0.35 

0.265 

0.18 
0.13 
0.12 
0.09 
0.07 
0.05

130 
130 
130 
160 
180 
180 
180 
210 
210

88 
88 
98 

105 
100 
100 
100 
100 
115 

 

105 
105 
105 
130 
150 
150 
150 
175 
175

130 
130 
130 
160 
180 
180 
180 
205 
205

11.5 

11.5 

10 
10 
10 
10 
10 
10









7

22 
22 
22 
25 
25 
25 
25 
25 
25







12 
15

35 
45 
50 
65 
75 
90 
90 

100 
100

M6 
M6 
M6 
M6 
M6 
M6 
M6 
M6 
M6

M5 
M5 
M6 
M6 
M8 
M8 

M10 
M10 
M10

65 
70 
75 
85 
80 
80 
80 
80 
95

50 
50 
50 
75 
75 
75 
75 
75 
75

114 
119 
139 

147.5 

155 
150 
155 
170 

182.8

X002491 
X002492 
X002493 
X002495 
X002497 
X002498 
X002555 
X002556 
X002557

2

200 V Class

VS−656RC5 
CIMR−R5A 

=

Current 

Value A

Inductance 

mH

Code No.

Fig.

Dimensions mm

Approx. Mass 

kg

Loss 

W

A

B

B1

C

D

E

F

H

J

K

L

M

43P7 
45P5 
47P5 
4011 
4015 
4018 
4022 
4030 
4037 
4045 
4055 
4075

10 
15 
20 
30 
40 
50 
60 
80 
90 

120 
150 
200

2.2 

1.42 
1.06 

0.7 

0.53 
0.42 
0.36 
0.26 
0.24 
0.18 
0.15 
0.11

130 
130 
160 
160 
180 
180 
180 
210 
210 
240 
240 
270

88 
98 
90 

105 
100 
100 
100 
100 
115 
126 
126 
162

130 
130 
130 
130 
150 
150 
150 
175 
175 
205 
205 
230

130 
130 
160 
160 
180 
180 
180 
205 
205 
240 
240 
260

11.5 
11.5 

10 
10 
10 
10 
10 
10 
10 


16









10 
10 
10

22 
22 
25 
25 
25 
25 
25 
25 
25 
25 
25 
40






8.5 

12 
15 
23 
23 
32

43 
50 
50 
65 
90 
90 
90 
95 

110 
130 
150 
135

M6 
M6 
M6 
M6 
M6 
M6 
M6 
M6 
M6 
M8 
M8 
M8

M4 
M4 
M5 
M5 
M6 
M6 
M6 
M8 
M8 

M10 
M10 
M10

65 
75 
70 
85 
80 
80 
75 
80 
95 

110 
110 
130

50 
50 
75 
75 
75 
75 
75 
75 
75 

150 
150 
150

− 
− 

115 

132.5 

140 
145 
150 
150 

177.5 

193 
198 
231

X002500 
X002501 
X002502 
X002503 
X002504 
X002505 
X002506 
X002508 
X002509 
X002566 
X002567 
X002568

2

1

400 V Class

Fig. 1

Fig. 2

U X

X

U

V

W

Y

Z

D

H

E

B

DETAIL IN 
MTG. HOLE

DETAIL IN 
MTG. HOLE

4-J:MTG. HOLES

4-J:MTG. HOLES

6-M:TERMINALS

6-M:TERMINALS

NAME 
PLATE

NAME PLATE

F

A

D

F

H

E

B

B1

A

L

K

L

K

V Y W Z

C

4.5

4.5

C

Summary of Contents for VARISPEED-656RC5

Page 1: ...T I F IED M A N A GEMENT SY S T E M JQA EM0498 QUALITY SYSTEM C ERT I F IED M A N A GEMENT SY S T E M JQA 0422 Certified for ISO9001 and ISO14001 VARISPEED 656RC5 200V CLASS 3 7 to 37kW 400V CLASS 3 7...

Page 2: ...Torque Power Operating Conditions 5000h year Electrical costs 0 12 kWh Electric Power Consumption P 55 5kW 2 33 3kW 15 11 1 2 3 7kW 2 25 9kW 5 48 1 2 0 9 0 95 8 49kW 4 82kW 3 67kW Electrical Costs 3...

Page 3: ...tage Fluctuation Allowable Frequency Fluctuation Imbalance Rate between Phases 380 to 460 VAC 50 60 Hz 15 to 10 3 Hz 300 ms Free phase rotation Within 2 150 for 30 sec 100 for 1 min 25 ED 80 continuou...

Page 4: ...AC MB MC Notes 1 Make sure to use the specified reactor fuse and fuse holder 2 Remove the wiring of terminals r l1 and s l2 since they were connected at the factory 3 Connect Varispeed G7 AC power sup...

Page 5: ...n Circuit Terminal Functions Type No Signal Function Signal Level Sequence Input S1 S2 S3 S4 SC SS SP M1 M2 M3 M4 MA MC MB MC AM AC Photocoupler Output Relay Output Multi functional Analog Output MANU...

Page 6: ...66 7 0 325 450 285 275 435 7 5 23 27 M6 330 610 285 275 435 87 5 200 300 205 186 285 8 0 6 6 M6 200 300 205 186 285 8 0 250 380 225 236 365 7 5 11 11 M6 250 380 225 236 365 7 5 140 280 180 126 266 7 0...

Page 7: ...W A 400 V Class Model CIMR R5A 23P7 3 7 13 70 60 130 25P5 5 5 19 70 60 130 27P5 7 5 26 90 80 170 2011 11 37 160 110 270 2015 15 51 200 130 330 2018 18 5 64 250 150 400 2022 22 77 320 180 500 2030 30 1...

Page 8: ...n level during a run 200 V class approx 150 VAC or less 400 V class approx 300 VAC or less Baseblock Circuit Error EEPROM Error CPU Internal A D Converter Error LED Display RUN DS1 DS2 Meaning Content...

Page 9: ...80 80 80 95 50 50 50 75 75 75 75 75 75 114 119 139 147 5 155 150 155 170 182 8 X002491 X002492 X002493 X002495 X002497 X002498 X002555 X002556 X002557 2 200 V Class VS 656RC5 CIMR R5A Current Value A...

Page 10: ...4015 4018 4022 4030 4037 4045 4055 4075 7 5 7 5 10 15 25 25 30 40 50 60 75 100 1 2 1 2 0 6 0 4 0 3 0 3 0 2 0 15 0 12 0 1 0 08 0 06 85 85 85 85 105 105 105 105 130 130 160 160 61 61 61 61 71 71 71 71 8...

Page 11: ...7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 CR6L 20 UL CR6L 100 UL CR6L 150 UL CMS 4 CMS 5 FU002091 FU002092 3 4 3 3 CR6L 30 UL CR6L 50 UL CR6L 75 UL FU002087 FU000927 FU000928 FU002088 F...

Page 12: ...T GASKET GASKET GASKET GASKET 2 5 DIA HOLES 4 M5 SCREWS 4 8 DIA HOLES C 4 8 DIA HOLES C 2 4 8 DIA HOLES D 25 25 61 610 8 309 4 5 C DC 25 300 325 12 5 7 5 19 5 27 12 5 4 5 571 625 187 61 C C C D 4 4 C...

Page 13: ...Digital Operator Extension Cable LED Monitor Digital Operator LED Monitor Model JVOP 139 Digital Operator Model JVOP 130 LED Monitor Digital Operator Extension Cable Panel Cutout Viewed from the fron...

Page 14: ...e and iodine at any time even during transportation or installation Operation Applying power to the VS 656RC5 DOUBLE CHECK WIRING AND SEQUENCE BEFORE TURNING THE POWER ON After turning the power of th...

Page 15: ...SHANGHAI CO LTD No 18 Xizang Zhong Road Room 1702 1707 Harbour Ring Plaza Shanghai 200001 China Phone 86 21 5385 2200 Fax 86 21 5385 3299 YASKAWA ELECTRIC SHANGHAI CO LTD BEIJING OFFICE Room 1011A Tow...

Reviews: