Kit Installation Procedure

1.

Collect the necessary installation tools and materials.

2.

Use the information in

Figure 2.1

and

Table 2.1

to make sure that SPC with the installed kit will fit in the

desired installation location:

Figure 2.1 Exterior and Mounting Dimensions

Table 2.1 UL Type 1 Kit Mounting Dimensions

SPC Model

Kit Number

Knockout

Dimension

Figure

Dimensions mm (in)

W

H

D

D1

H1

H2

2015

2022

4022

4030

UUX001686

Figure 2.2

256

(10.08)

541

(21.30)

254

(10.00)

100

(3.94)

423

(16.65)

118

(4.65)

2030

4037

4045

UUX001687

Figure 2.3

310

(12.20)

688

(27.09)

264

(10.43)

106

(4.17)

525

(20.67)

163

(6.42)

2037

2045

4056

UUX001703

Figure 2.4

310

(12.20)

847

(33.34)

290

(11.43)

106

(4.17)

636

(25.04)

210

(8.27)

4090

UUX001703

Figure 2.5

310

(12.20)

847

(33.34)

375

(14.77)

191

(7.51)

636

(25.04)

210

(8.27)

W

D

D1

H2

H1

H

Summary of Contents for UUX001686

Page 1: ...rive Option Installation Manual Type UUX001686 UUX001687 UUX001703 Models 200 V class 20 to 60 HP 400 V class 30 to 125 HP To properly use the product read this manual thoroughly and retain for easy r...

Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual...

Page 3: ...n Manual 3 Table of Contents 1 Preface and General Safety 4 General Description 4 Option Package Contents 4 Applicable Documentation 4 General Safety 5 2 Kit Installation 7 Section Safety 7 Installati...

Page 4: ...crew 4 ea USP04765 1 Applicable Documentation Document Description YASKAWA AC Drive Option UL Type 1 Kit for Single Phase Converter Installation Manual Read this manual before you install this option...

Page 5: ...ING Sudden Movement Hazard System may start unexpectedly when the unit is energized resulting in death or serious injury Clear all personnel from the converter drive motor and machine area before ener...

Page 6: ...e equipment if a fuse is blown or a Ground Fault Circuit Interrupter GFCI is tripped Repair the cause of the problem prior to re energizing the equipment Check the wiring and the selection of the peri...

Page 7: ...ing the converter inside an enclosed panel or cabinet When multiple drives are placed inside the same enclosure panel install proper cooling to ensure air entering the enclosure does not exceed 40 C F...

Page 8: ...xterior and Mounting Dimensions Table 2 1 UL Type 1 Kit Mounting Dimensions SPC Model Kit Number Knockout Dimension Figure Dimensions mm in W H D D1 H1 H2 2015 2022 4022 4030 UUX001686 Figure 2 2 256...

Page 9: ...2 50 1 97 44 1 73 35 1 38 Figure 2 3 Frame 2 Conduit Knockout Dimensions Table 2 3 Frame 2 Conduit Knockout Dimensions Dimensions mm in D D1 W W1 W2 W3 W4 W5 d2 d3 d4 d5 48 1 89 157 6 19 94 5 3 72 68...

Page 10: ...in D D1 D2 W W1 W2 W3 d3 d4 d5 79 3 11 155 6 09 106 4 17 75 2 95 65 2 56 22 3 0 88 90 3 54 50 1 97 35 1 38 62 2 44 Figure 2 5 Frame 3B Conduit Knockout Dimensions Table 2 5 Frame 3B Conduit Knockout D...

Page 11: ...ded M4 x 10 captive pan head screws to attach the top cover Tighten the screws to a tightening torque of 0 98 to 1 33 N m 8 67 to 11 77 in lb Figure 2 6 Attach the Top Cover 4 Remove the two bottom li...

Page 12: ...67 to 11 77 in lb Note Kit UUX001783 ships with two heatsink covers Use the information in Table 2 6 to select the correct cover The part number is stamped on the part for identification You can disc...

Page 13: ...the screws to a tightening torque of 3 92 to 4 90 N m 34 69 to 43 37 in lb Figure 2 9 Attach the Bottom Housing 7 Remove the necessary conduit knockouts To remove a conduit knockout insert the tip of...

Page 14: ...to the manual packaged with the SPC for wiring instructions Figure 2 11 Wire the SPC 9 Use the provided M4 x 10 truss head screws to attach the bottom cover Tighten the screws to a tightening torque o...

Page 15: ...ion YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual 15 10 The kit installation is complete and the SPC is now enclosed in a UL Type 1 enclosure Figure 2 13 Installati...

Page 16: ...16 YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual Revision History Date of Publication Revision Number Section Revised Content February 2019 First Edition...

Page 17: ...YASKAWA TOEPYAISPC03 UL Type 1 Kit for Single Phase Converter Installation Manual 17...

Page 18: ...reign Trade Regulations Therefore be sure to follow all procedures and submit all relevant documentation according to any and all rules regulations and laws that may apply Specifications are subject t...

Reviews: