n
Drive Models 4
o
0720 to 4
o
0930
+
-
+
-
+
+
-
+
-
+
+
-
S
1
S
2
S
3
S
4
S
5
S
6
S
7
MP
DM
DM
RP
A
1
A
2
A
3
0 V
AC
R
R
S
S
-
IG
H
1
H
2
HC
2 k
S
8
SC
0 V
0 V
AC
FM
AM
AC
E (G)
S
1
S
2
<18>
<12>
<19>
<17>
<13>
<10>
<15>
<12>
<8>
+
24 V
+
V
MA
M
1
M
2
MB
MC
Forward Run / Stop
Reverse Run / Stop
External fault
Fault reset
Multi-speed step 1
Multi-speed step 2
External Baseblock
Jog speed
Multi-function
digital inputs
(default setting)
Sink / Source mode
selection wire link
(default: Sink)
CN5-C
CN5-B
CN5-A
Option board
Pulse Train Input
(max 32 kHz)
Shield ground
terminal
Multi-function
analog/pulse
train inputs
Power 10.5 Vdc, max. 20 mA
Analog Input 1 (Frequency Reference Bias)
0 to +/-10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
Analog Input 2 (Frequency Reference Bias)
0 to +10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
Analog Input 3 (Aux. Frequency Reference)
0 to +/-10Vdc (20 kΩ)
4 to 20 mA (250 Ω) / 0 to 20 mA (250 Ω)
-
V
Power supply, -10.5 Vdc, max. 20 mA
Safety
switch
MEMOBUS/Modbus comm.
RS-422/RS-485
max. 115.2 kbps
Safe Disable inputs
Wire
jumper
Open
Safety relay /
controller
Termination resistor
(120 , 1/2 W)
DIP
Switch S2
Fault relay output
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
Multi-function relay output (During Run)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
Multi-function pulse train output
(Output frequency)
0 to 32 kHz (2.2 k )
Multi-function analog output 1
(Output frequency)
-10 to +10 Vdc (2mA)
or 4 to 20 mA
EDM (Safety Electronic Device Monitor)
shielded line
twisted-pair shielded line
main circuit terminal
control circuit terminal
M
3
M
4
Multi-function relay output (Zero Speed)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
M
5
M
6
Multi-function relay output (Speed Agree 1)
250 Vac, max. 1 A
30 Vdc, max 1 A
(min. 5 Vdc, 10 mA)
SP
SN
<14>
AM
FM
V
I
V
I
DIP Switch S1
A2 Volt/Curr. Sel
DIP Switch S4
A3 Analog/PTC
Input Sel
PTC
AI
Off
On
DIP Switch S2
Term. Res. On/Off
Jumper S3
H1, H2
Sink/Source Sel.
Jumper S5
AM/FM Volt./Curr.
Selection
Terminal board
jumpers and switches
FM
+
-
AM
<9>
<16>
Ω
Ω
<17>
Multi-function analog output 2
(Output current)
-10 to +10 Vdc (2mA)
or 4 to 20 mA
A+
A
-
B
-
Z
-
B+
Z+
a+
a-
b+
b-
z+
z-
FE
IP
IG
TB1
SD
TB2
PG
-
X3
connectors
(option)
Ω
<11>
<7>
24
0
FE
24 V
0 V
<21>
<20>
Drive
<6>
<5>
Control Circuit
p1
n1
Main Circuit
<3>
<4>
Terminals p1 and n1 are for
momentary power loss recovery
unit. Do not connect to AC power
supply.
MC
2MCCB
MB
ON
OFF
THRX
SA
1
2
TRX
MC MA
TRX
Fault relay
contact
Braking resistor unit
Thermal relay trip contact
MC
MC
SA
SA
THRX
Harmonic
filter module
X
Y
Z
R/L1
S/L2
T/L3
X1
Y1
Z1
X1
Y1
Z1
p2
n2
p2
n2
r1/ℓ11
t1/ℓ31
CN500
(20pin)
CN500
(20pin)
X
Y
Z
r1/ℓ11
t1/ℓ31
2MCCB
1/ℓ21
1/ℓ21
ELCB (MCCB)
R
T
S
MC
Three-phase
power supply
380 to 500 V
50/60 Hz
Wiring sequence should shut off
power to the drive when a fault
output is triggered.
If running from a 400 V power
supply, a step-down transformer
is needed to
reduce the voltage to 200 V.
<1>
B track monitor
A track monitor
M
U/T
1
V/T
2
W/T
U
V
W
3
Ground
PG
<2>
Cooling fan
M
FU
FV
FW
24 V Control Power Supply
Unit Terminals
Slide Switch S6
DM+, DM-
N.C./N.O. Selection
N.C.
Figure 3.2 Drive Standard Connection Diagram (Example: Model 4
o
0720)
3.2 Standard Connection Diagram
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
81
3
Electrical Installation
Summary of Contents for U1000 iQpump Drive
Page 705: ......