u
A2: User Parameters
No.
(Addr.
Hex)
Name
LCD Display
Description
Values
Page
A2-01 to
A2-32
(0106 to
0125)
User Parameters 1 to 32
User Param 1 - 32
All Modes
Recently edited parameters are listed here. The user can also
select parameters to appear here for quicker access.
Default:
Range: b1-01 to
o4-19
A2-33
(0126)
User Parameter
Automatic Selection
User Parms Sel
0: Disabled
1: Enabled
All Modes
0: Parameters A2-01 to A2-32 are reserved for the user to create
a list of User Parameters.
1: Save history of recently viewed parameters. Recently edited
parameters will be saved to A2-17 through A2-32 for quicker
access.
Default: 1
Range: 0, 1
<1> Default setting value is determined by the Application Preset selected in parameter A1-06.
<2> This setting is the default setting of the Setup Group parameters.
Refer to Setup Group Parameters on page 145
B.3 A: Initialization Parameters
YASKAWA ELECTRIC SIEP C710636 04D U1000 Industrial MATRIX Drive Technical Manual
493
B
Parameter List
Summary of Contents for U1000 iQpump Drive
Page 705: ......