364
YASKAWA ELECTRIC
SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
B.4 Control Mode Dependent Parameter Default Values
B.4 Control Mode Dependent Parameter Default Values
The tables below list parameters that depend on the control mode selection (A1-02 for motor 1, E3-01 for motor 2).
These parameters are initialized to the shown values if the control mode is changed.
Table B.1 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values
Table B.2 E3-01 (Motor 2 Control Mode) Dependent Parameters and Default Values
Note:
Motor 2 cannot be a PM motor.
Parameter
<9> Default setting is determined by the motor code set to parameter E5-01.
<11> Default setting is determined by the drive model selection set in parameter o2-04.
<17> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
Description
Setting Range
Resolution
Control Modes (A1-02)
V/f (0)
OLV (2)
PM (5)
b2-03
DC Injection Braking Time at Start
0.00 to 10.00
0.01 s
0.00
0.00
–
b2-04
DC Injection Braking Time at Stop
0.00 to 10.00
0.01 s
0.50
0.50
0.00
b3-02
Speed Search Deactivation Current
0 to 200
1%
120
100
–
C2-01
S-Curve Characteristic at Accel Start
0.00 to 10.00
0.01 s
0.20
0.20
1.00
C3-01
Slip Compensation Gain
0.0 to 2.5
0.1
0.0
1.0
–
C3-02
Slip Compensation Primary Delay Time
0 to 10000
1 ms
2000
200
–
C4-01
Torque Compensation Gain
0.00 to 2.50
0.01
1.00
1.00
0.00
C4-02
Torque Compensation Primary Delay Time
0 to 10000
1 ms
200
20
100
C6-02
Carrier Frequency Selection
1 to 6, F
1
2
E1-04
Maximum Output Frequency
40.0 to 400.0
0.1 Hz
50.0
50.0
E1-05
Maximum Voltage
0.0 to 255.0
0.1 V
200.0
200.0
E1-06
Base Frequency
0.0 to 400.0
0.1 Hz
50.0
50.0
E1-07
Middle Output Frequency
0.0 to 400.0
0.1 Hz
2.5
3.0
–
E1-08
Middle Output Frequency Voltage
0.0 to 255.0
0.1 V
16.0
12.0
–
E1-09
Minimum Output Frequency
0.0 to 400.0
0.1 Hz
1.3
0.5
E1-10
Minimum Output Frequency Voltage
0.0 to 255.0
0.1 V
12.0
3.0
–
E1-11
Middle Output Frequency 2
0.0 to 400.0
0.1 Hz
0.0
0.0
–
E1-12
Mid Output Frequency Voltage 2
0.0 to 255.0
0.1 V
0.0
0.0
–
E1-13
Base Voltage
0.0 to 255.0
0.1 V
0.0
0.0
–
L1-01
Motor Overload Protection Selection
0 to 4
-
1
1
4
L8-18
Software Current Limit Selection
0, 1
1
1
1
–
S6-04
Main Circuit Voltage Adjustment Gain
0.00 to 5.00
0.01
1.00
0.30
0.65
S6-05
Accel/Decel Calculation Gain
0.00 to 200.00
0.01
1.00
1.00
2.50
Parameter
<17> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
Description
Setting Range
Resolution
Control Modes (E3-01)
V/f (0)
OLV (2)
E3-04
Motor 2 Max Output Frequency
40.0 to 400.0
0.1 Hz
50.0
50.0
E3-05
Motor 2 Max Voltage
0.0 to 255.0
0.1 V
200.0
200.0
E3-06
Motor 2 Base Frequency
0.0 to 400.0
0.1 Hz
50.0
50.0
E3-07
Motor 2 Mid Output Frequency
0.0 to 400.0
0.1 Hz
2.5
3.0
E3-08
Motor 2 Mid Output Frequency Voltage
0.0 to 255.0
0.1 V
16.0
14.4
E3-09
Motor 2 Minimum Output Frequency
0.0 to 400.0
0.1 Hz
1.3
0.5
E3-10
Motor 2 Minimum Output Frequency Voltage
0.0 to 255.0
0.1 V
12.0
2.5
E3-11
Motor 2 Mid Output Frequency 2
0.0 to 400.0
0.1 Hz
0.0
0.0
E3-12
Motor 2 Mid Output Frequency Voltage 2
0.0 to 255.0
0.1 V
0.0
0.0
E3-13
Motor 2 Base Voltage
0.0 to 255.0
0.1 V
0.0
0.0
E4-14
Motor 2 Slip Compensation Gain
0.0 to 2.5
0.1
0.0
1.0