- 4 -
NOTE
Fig. 1 PROFIBUS-DP Communications Interface Unit SI-P1/V7
1 OUTLINE OF PRODUCT
The PROFIBUS-DP Communication Interface Unit SI-P1/V7 is an option unit that can be mounted on the VS-606V7 Inverter and
used for communications with the PROFIBUS-DP master.
Three types of I/O data length (32 bytes, 12bytes, 6bytes) can be selected. The run/stop status can be monitored and the inverter
internal constants can be set/changed from the PROFIBUS-DP master.
The SI-P1/V7 unit can be mounted on these inverters.
VS-606V7:Standard series (Operates on inverter software No.0020 or later edition)
Name
Code No.
Function
SI-P1/V7
PROFIBUS-DP
Communication
Interface Unit
SI-P1/V7
73606-V711X
PROFIBUS data
Extended data 1 (Data length:32 bytes)
High-speed I/O data area (input:16bytes, output 16bytes)
MEMOBUS message (input:16bytes, output 16bytes)
Extended data 2 (Data length:12bytes)
High-speed I/O data area (input:4bytes, output 4bytes)
MEMOBUS message (input:8bytes, output 8bytes)
Basic data (Data length:6 bytes)
High-speed I/O data area (input:6bytes, output 6bytes)
Communication speed:9.6kbps to 12Mbps
Specify the name and code number when ordering the PROFIBUS-DP Communications Interface Unit SI-P1/V7.
LED
Modular Plug (CN1)
Ground Terminal
Optional
Connector
(CN2)
Front of the SI-P1/V7 Unit
Rear of the SI-P1/V7 Unit
Terminal
Block
Termination
Resistor Selector
Switch
Address Switch2
5.5m
m
Address Switch1