Safety Information

Read this instruction manual and the related documents thoroughly before installation, operation, maintenance or inspection of this
product.    Make sure you understand product information,all precautions and safety information before using the product.    Also,
keep this manual in a convenient location so that it can be referred to whenever necessary.

The following conventions are used to indicate precautions in this manual.

Indicates precautions that, if not heeded, could possibly result in loss of
life or serious injury.

Indicates precautions that, if not heeded, could result in relatively serious
or minor injury, damage to the product, or faulty operation.

Even items described in 

CAUTION

 

 

may result in a vital acccident in some situations.

In either case, follow these important notes.

                        : Items to be observed by users are described in the relevant sections.

 WARNING

 

After turning OFF the main circuit's power supply, wait until the CHARGE indicator
light goes out before connecting wires to the connectors or to the external terminals
of the SI-P1/V7.

The capacitor will remain charged and is dangerous.

 CAUTION

 

A CMOS IC is used for the SI-P1/V7 unit.    Handle the control board and CMOS IC
carefully.    The CMOS IC can be destroyed by static electricity if touched directly.

 

To remove the SI-P1/V7 unit from the inverter and transport or store it separately,
keep the optional unit in the anti-static electricity package used to protect the unit at
delivery.

 

Do not change the wiring or remove/insert the connectors while the power is turned
ON.

Failure to observe this caution may result in injury.

: Before Use

(1) Read this instruction manual, SI-P1/V7 User’s Manual and the instruction manual of the inverter on

which this optional unit is mounted before using the PROFIBUS-DP Communications Interface Unit
SI-P1/V7.

(2) The GSD file, which is not included with the SI-P1/V7, is needed to use the SI-P1/V7 in the

PROFIBUS-DP slave.    When the slave is registered in the GSD file in the PROFIBUS-DP master,
the master also recognizes the SI-P1/V7 unit, and then the SI-P1/V7 can be used in the registered
slave.    To obtain the GSD file, please contact your Yaskawa representative.

NOTE

CAUTION

WARNING

NOTE

Summary of Contents for SI-P1/ V7

Page 1: ...TOBZ C736 70 4B Upon receipt of the product and prior to initial operation read these instructions thoroughly and retain them for future reference PROFIBUS DP INTERFACE UNIT VS 606 V7 OPTION UNIT INS...

Page 2: ...s to the connectors or to the external terminals of the SI P1 V7 The capacitor will remain charged and is dangerous CAUTION A CMOS IC is used for the SI P1 V7 unit Handle the control board and CMOS IC...

Page 3: ...e No Function SI P1 V7 PROFIBUS DP Communication Interface Unit SI P1 V7 73606 V711X PROFIBUS data Extended data 1 Data length 32 bytes High speed I O data area input 16bytes output 16bytes MEMOBUSmes...

Page 4: ...ts missing Check the parts list see 2 2 Contact your Yaskawa representative immediately if any problem should be found concerning the shipment 2 1 Nameplate The following diagram shows the nameplate o...

Page 5: ...are in the top half The wiring to the inverter must be completed in advance After mounting the SI P1 V7 unit the terminal for inverter is hidden from view 6 Refer to Fig 2 for the location of the scre...

Page 6: ...P1 V7 PROFIBUS DP bus connection terminals Table 2 Function of PROFIBUS DP Bus Connection Terminals Terminal No Name Explanation 1 5V BUS Not used 2 GND BUS Not used 3 A Line Minus RxD TxD according t...

Page 7: ...7 Unit 6 1 1 Address Switch Rotary address switches to set the slave address on the PROFIBUS DP are provided Setting address switches 1 and 2 on the SI P1 V7 unit can be used to set the inverter addre...

Page 8: ...D file name for the SI P V7 unit however the GSD file version is different Previous GSD file Revision Version1 0 New GSD file Revision Version3 1 Contact your Yaskawa representative to get the new GSD...

Page 9: ...0 Brazil Phone 55 11 3585 1100 Fax 55 11 5581 8795 YASKAWA ELECTRIC EUROPE GmbH Hauptstra e 185 65760 Eschborn Germany Phone 49 6196 569 300 Fax 49 6196 569 398 YASKAWA ELECTRIC UK LTD 1 Hunt Hill Orc...

Reviews: