9 Input Assemblies (Drive Produces)
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
59
Input Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Parameter [F7-39], Default: NetRef and NetCtrl (High Byte)
17
Parameter [F7-40], Default: Drive Software Version (Low Byte)
Parameter [F7-40], Default: Drive Software Version (High Byte)
18
Parameter [F7-41] (Low Byte), Default: Not Used
Parameter [F7-41] (High Byte), Default: Not Used
19
Parameter [F7-42] (Low Byte), Default: Not Used
Parameter [F7-42] (High Byte), Default: Not Used
20
40
-
-
-
-
-
-
Assy. 116 F7-
32 Error
Assy. 116 F7-
31 Error
41
Assy. 116 F7-
30 Error
Assy. 116 F7-
29 Error
Assy. 116 F7-
28 Error
Assy. 116 F7-
27 Error
Assy. 116 F7-
26 Error
Assy. 116 F7-
25 Error
Assy. 116 F7-
24 Error
Assy. 116 F7-
23 Error
21
42
-
-
-
-
-
-
Assy. 166 F7-
42 Error
Assy. 166 F7-
41 Error
43
Assy. 166 F7-
40 Error
Assy. 166 F7-
39 Error
Assy. 166 F7-
38 Error
Assy. 166 F7-
37 Error
Assy. 166 F7-
36 Error
Assy. 166 F7-
35 Error
Assy. 166 F7-
34 Error
Assy. 166 F7-
33 Error
*1
Selectable with F7-33 to F7-42.
Name
Description
Running
Running
0: Stop
1: Forward or Reverse Running
ZSP
Zero Speed
0: Running
1: Stop or DC Injection Braking
REV Running
Reverse Running
0: Not Reverse Running
1: Reverse Running
Fault Reset
Fault Reset
0: -
1: Fault Reset
Speed Agree
Speed Agree
0: -
1: Speed actual at speed reference
Ready
Ready
0: Not Ready
1: Ready
Alarm
Alarm
0: No Alarm
1: Alarm
Faulted
Faulted
0: No Fault
1: Fault
oPE
oPE
0: -
1: oPExx
Uv
Undervoltage
0: -
1: Undervoltage
LOCAL/REMOTE
Run command is from network
0: Run command is not from network
1: Run command is from network
Multi-Function Digital Output 1
Terminal M1/M2 (varies by drive model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Multi-Function Digital Output 2
Terminal M3/M4 (varies by drive model)
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.