2 CHECKING ON DELIVERY
E - 8
2.4
Mounting FC100 Unit
Mount a FC100 Unit on a SGDH SERVOPACK in the following manner. Provide the screws
for connecting ground wire as shown below.
Mounting
Method
SERVOPACK Type
Screw
Remarks
Base
mounted
SGDH-A3 to 02BE
SGDH-A3 to 10AE
M3
×
10 round head screws
(with spring washer and
plain washer)
Attachments.
SGDH-15 to 50AE
SGDH-05 to 30DE
M4
×
10 round head screws
(with spring washer and
plain washer)
Attachments.
SGDH-60/75AE
M4
×
8 round head screws
(with spring washer and
plain washer)
Use the screw of the front panel.
Rack
mounted
SGDH-A3 to 02BE-R
SGDH-A3 to 50AE-R
SGDH-05 to 30DE-R
M4
×
6 round head screws
(with spring washer and
plain washer)
Attachments.
Note : Make sure that spring washers and
plain washers are used for mounting.
(Otherwise, the screw for connecting
ground wire sticks out from the other
side of the flange, and the SERVO-
PACK cannot be mounted properly.)
Duct
ventilated
SGDH-60/75AE-P
M4
×
8 round head screws
(with spring washer and
plain washer)
Use the screw of the front panel.
1. Remove the connector cover mounted on CN10 of SERVOPACK.
MODE/SET
DATA/
CHARGE POWER
SGDH
−
SERVOPACK
YASKAWA
CN10
Connector
cover
2. Mount a FC100 Unit.
SGDH
−
SERVOPACK
YASKAWA
F 1
C 00
C
N
4
CN10
Connector (to SERVOPACK)