15.14 Torque Limit Function
15-44
15.14
Torque Limit Function
Max Torque (6072h)
This object sets the maximum output torque for the motor. Set the value in units of 0.1% of the
motor rated torque.
The maximum motor torque is automatically set in this object when the power is turned ON.
Positive Torque Limit Value (60E0h)
This object sets the positive torque limit. Set the value in units of 0.1% of the motor rated
torque.
Negative Torque Limit Value (60E1h)
This object sets the negative torque limit. Set the value in units of 0.1% of the motor rated
torque.
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
6072h
0
Max torque
UINT
RW
Yes
0 to 65,535
(default: maximum
motor torque) [0.1%]
No
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
Saving to
EEPROM
60E0h
0
Positive torque limit
value
UINT
RW
Yes
0 to 65,535
(default: 8,000) [0.1%]
Yes
Index
Subin-
dex
Name
Data
Type
Access
PDO
Mapping
Value
EEPROM
60E1h
0
Negative torque limit
value
UINT
RW
Yes
0 to 65,535
(default: 8,000) [0.1%]
Yes