13.4 Utility Function (Fn
) Operations on the Panel Operator
13.4.17 Display Software Version (Fn012)
13-25
13
Panel Displays and Panel Operator Pr
ocedur
es
13.4.17 Display Software Version (Fn012)
Refer to the following section for information on this utility function other than the procedure.
9.1 Monitoring Product Information
5
Example
•
Rotary Servomotors
Press the
MODE/SET
Key. The encoder type
and resolution codes will be displayed.
*
A single-turn absolute encoder is used only for
a Direct Drive Servomotor.
•
Linear Servomotors
Press the
MODE/SET
Key. The encoder type and
linear encoder scale pitch resolution codes will be
displayed.
6
Press the
MODE/SET
Key. The code for custom
SERVOPACK specifications will be displayed.
y.0000
indicates a standard model. If anything other than
y.0000
is displayed, a customized SERVOPACK is
being used.
7
Press the
DATA/SHIFT
Key for approximately one
second to return the display to
Fn011
.
Continued from previous page.
Step
Panel Display after
Operation
Keys
Operation
MODE/SET
DATA/
00
01
02
20
22
24
Encoder Type
Encoder Re
s
olution
No.
Re
s
olution
20 bit
s
22 bit
s
24 bit
s
No.
Type
Incremental
S
ingle-turn ab
s
olute
*
Multiturn ab
s
olute
256
4096
8
12
00
01
No.
Type
Incremental
Ab
s
olute
Encoder Type
Linear Encoder
S
cale Pitch Re
s
olution
No.
Re
s
olution
MODE/SET
DATA/
S
pecification
s
code
MODE/SET
DATA/
Step
Panel Display after
Operation
Keys
Operation
1
Press the
MODE/SET
Key to enter Utility Function
Mode.
2
Press the
UP
Key or
DOWN
Key to display
Fn012
.
3
Press the
DATA/SHIFT
Key for approximately one
second. The software version of the SERVOPACK will
be displayed.
Continued on next page.
MODE/SET
DATA/
MODE/SET
DATA/
MODE/SET
DATA/