13.1 Device Control
13.1.1 State Machine Control Commands
13-4
13.1.1
State Machine Control Commands
13.1.2
Bits in Statusword (6041 Hex)
13.1.3
Related Objects
Command
Bits in Controlword (6040 Hex)
Bit 7
Bit 3
Bit 2
Bit 1
Bit 0
Shutdown
0
−
1
1
0
Switch ON
0
0
1
1
1
Switch ON + Enable Operation
0
1
1
1
1
Disable Voltage
0
−
−
0
−
Quick Stop
0
−
0
1
−
Disable Operation
0
0
1
1
1
Enable Operation
0
1
1
1
1
Fault Reset
0
→
1
−
−
−
−
Bit
Data Description
Remarks
0
Ready to Switch ON
Refer to the following section for details.
1
Switched ON
2
Operation Enabled
3
Fault
4
Voltage Enabled
5
Quick Stop
6
Switch ON Disabled
7
Warning
8
Active Mode Stop
9
Remote
10
Target Reached
11
Internal Limit Active
12
Operation Mode Specific
13
14
Torque Limit Active
15
Safety Active
Index
Subindex
Name
Access
PDO
Mapping
Unit
Data
Type
6040 hex
0
Controlword
RW
Yes
−
UINT
6041 hex
0
Statusword
RO
Yes
−
UINT
605A hex
0
Quick stop option code
RW
No
−
INT
605B hex
0
Shutdown option code
RW
No
−
INT
605C hex
0
Disable operation option code
RW
No
−
INT
605D hex
0
Halt option code
RW
No
−
INT
605E hex
0
Fault reaction option code
RW
No
−
INT