1.3 Part Names
1.3.2
Σ
-7C
1-5
1
Ba
s
ic Information on
S
ER
VOP
ACK
s
1.3.2
Σ
-7C
Rotary Switches (S1 and S2) Used to set the MECHATROLINK station address.
PWR
Lights when the control power is being supplied.
–
L1, L2
Lights during MECHATROLINK communications.
–
CN
Lights when the SERVOPACK normally receives a CON-
NECT command.
–
Analog Monitor Connector
(CN5)
You can use a special cable (peripheral device) to monitor
the motor speed, torque reference, or other values.
–
Panel Display for Axis A
Displays the servo status with a seven-segment display.
–
Panel Display for Axis B
Safety Connector (CN8)
Connects to a safety function device.
Continued from previous page.
No.
Name
Description
Reference
17
18
19
20
21
22
23
24
No.
Name
Description
Reference
Front Cover
–
–
Input Voltage
–
–
Nameplate
Indicates the SERVOPACK model and ratings.
–
Model
The model of the SERVOPACK.
–
QR Code
The QR code that is used by the MechatroCloud service.
–
CHARGE
Lit while the main circuit power is being supplied.
Note: Even if you turn OFF the main circuit power supply, this indi-
cator will be lit as long as the internal capacitor remains
charged. Do not touch the main circuit or motor terminals
while this indicator is lit. Doing so may result in electric
shock.
–
Main Circuit Terminals
The terminals depend on the main circuit power supply
input specifications of the SERVOPACK.
–
Continued on next page.
Bottom of the
S
ERVOPACK
26
26
L2
L1
L
3
L1C
L2C
B1/
B2
B
3
12
W
A
VA
UA
Motor terminal
s
11
11
12
12
1
3
1
3
16
16
2
3
2
3
17
17
18
18
19
19
15
15
14
14
24
24
25
25
22
22
20
20
21
21
S
ERVOPACK with the Front Cover Open
Main circuit terminal
s
(on
s
ide of
S
ERVOPACK)
With the Front Cover Open