5 Compliance with CE Marking
E-21
5 Compliance with CE Marking
5.1 Installation Conditions of EMC Directive
To adapt the EMC directives (EN55011 group1 classA, EN61800-3) for a
combination test using servomotors and SERVOPACKs from the
Σ
-V
series, a ferritic core, a noise filter, or a surge absorber must be used. For
details, read the Installation instructions in
Σ
-V series User’s Manual Setup
Rotational Motor
(SIEPS80000043) or
Σ
-V series User’s Manual Setup Lin-
ear Motor
(SIEPS80000044).
However, because this product is built-in, check that the following condi-
tions are still met after being installed in the final product.
5.2 Conditions Corresponding to Low Voltage Direc-
tive
To adapt SERVOPACKs to the Low Voltage Directive, make sure that the
following environmental conditions are met.
• Installation category: III
• Pollution degree: 2
• Protection class: 10
• Altitude: 1000 m max.
Be sure to install a fuse for the main circuit power-supply as well as meeting
these environmental conditions. To choose the fuse capacity, refer to 3.1
Model-case Circuit Breaker and Fuse Capacity.