![YASKAWA PVI 23 TL Installation And Operation Manual Download Page 20](http://html1.mh-extra.com/html/yaskawa/pvi-23-tl/pvi-23-tl_installation-and-operation-manual_3484906020.webp)
PVI 23TL, 28TL Installation and Operation Manual (Rev J)
DOCR-070365-J
Page
19
of
66
Figure 3.7 – Remove Cover Plate of Main Housing
6. Using a #2 Philips screw driver, remove
cover plate on the bottom of main
housing.
Figure 3.8 – Remove Cover of Wiring Box
7. Using a #2 Philips screw driver, remove
cover of wiring box and keep the cover (it
can be re-secured later onto the
enclosure).
Figure 3.9 – Connecting the Wire Box to the Main
Housing
8. Connect the wiring box to the main
housing using four M6*16 screws
(available in accessory box).
Torque = 25in-lbs