Fieldbus PCI-Card
Card
10.2.1 Status LEDs
No:
Indication
State
Meaning
1
Appl.
connected
Green
Controlled by application
Red
Standalone
2
I/O ACCESS
Green, flashing
I/O ACCESS
Red, flashing
Off
3
Activity
Green, flashing
A packet is received or transmitted
4
-
Green,
Link detected
Off
Link not detected
5
Network status
Green
On-line, one or more connections
established (CIP Class 1 or 3)
Green, flashing
On-line, no connections established
Red
Duplicate IP- Configured IP address already
in use
Red, flashing
Connection timeout. One or more of the
connections in which this module is the
target has timed-out. This state is only left if
all timed-out connections are re-established
or if the module is reset.
Alternating red/
green
Self test in progress
Off
No power or no IP address
6
Module status
Green
Controlled by a Scanner in Run state
Green, flashing
Not configured, or Scanner in Idle state
Red
A major unrecoverable fault has been
detected
Red, flashing
A minor recoverable fault has been detected
Alternating red/
green
Self-test in progress
Off
No power
Fieldbus interface
1
8
Fig. 43 RJ45 female layout
Pin RJ45
(Female)
Signal
1
TD+
2
TD-
3
RD+
4
Termination
Page 50
Reg.No. ME00107EN-02