Fieldbus PCI-Card
General
2 Installation
2.1
General
2.1.1
Specification
• 3.3 and 5 V support (Universal keyed add-in)
• Competitively priced - high performance
• Easy plug-and-play interface
2.1.2
Technical specification
• Size(W x L x D): 100 x 120 22 mm (3.94” x 4.72” x 0.87”)
• Power supply: 3.3 and 5 V, 600 mA VDC
• Temperature: operating 0° +55°C
2.1.3
Compliances and conformances
• EMC compliance: 2004/108/EC
a. Emission: EN 61000-6-4:2001
b. Immunity: EN 61000-6-2:2001
• CE marked
• UL conformance
• Tested and verified for Fieldbus and network conformance
• RoHS compliance
2.2
Hardware installation
Warning
To prevent electrical shock to personnel and to prevent equipment damage, ensure
power to the robot control system is turned OFF before beginning the installation.
Caution
Never change any of the settings on the PCI-card while controller power is ON.
Caution
The card contains ESD sensitive components. Observe ESD precautions when handling the
card.
The following installation instructions apply to all fieldbus PCI-cards delivered by YASKAWA.
Reg.No. ME00107EN-02